Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,476

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0306 # 03 Y:2005 03 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,056 $1,000 Implemented
MI0105 # 03 Y:2005 03 2005 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $26,325 $32,000 Not Implemented
MS0274 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,508 $2,000 Not Implemented
BD0287 # 07 Y:2005 07 2005 INSTALL TURBULATORS $1,486 $2,500 Not Implemented
SU0212 # 05 Y:2005 05 2005 INSTALL TURBULATORS $985 $571 Not Implemented
GT0808 # 06 Y:2005 06 2005 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $16,309 $15,800 Not Implemented
BD0288 # 03 Y:2005 03 2005 REPLACE BOILER $14,342 $2,500 Implemented
AS0401 # 03 Y:2005 03 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $6,374 $5,000 Not Implemented
AS0401 # 06 Y:2005 06 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $721 $1,300 Not Implemented
UD0717 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,225 $0 Implemented
SU0209 # 05 Y:2005 05 2005 INSTALL TURBULATORS $1,988 $500 Not Implemented
WV0315 # 03 Y:2005 03 2005 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $4,606 $3,300 Not Implemented
WV0315 # 02 Y:2005 02 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,726 $1,000 Implemented
LE0210 # 02 Y:2005 02 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,088 $750 Implemented
WV0313 # 11 Y:2005 11 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,420 $1,000 Implemented
WV0313 # 03 Y:2005 03 2005 OPERATE BOILERS ON HIGH FIRE SETTING $27,626 $5,110 Not Implemented
UU0083 # 01 Y:2005 01 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,340 $2,000 Not Implemented
MA0573 # 02 Y:2005 02 2005 REPLACE BOILER $5,500 $15,900 Not Implemented
UD0715 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,021 $0 Implemented
OR0480 # 03 Y:2005 03 2005 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $493 $0 Implemented
SD0358 # 01 Y:2005 01 2005 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $10,212 $3,850 Not Implemented
GT0799 # 01 Y:2005 01 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,890 $450 Not Implemented
UD0714 # 10 Y:2005 10 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,296 $0 Implemented
UM0279 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,890 $500 Implemented
OK0704 # 02 Y:2005 02 2005 OPERATE BOILERS ON HIGH FIRE SETTING $4,358 $1,436 Not Implemented