Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,476

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TP0015 # 01 Y:2000 01 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,906 $600 Implemented
WI0371 # 11 Y:2000 11 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $282 $500 Implemented
WI0370 # 09 Y:2000 09 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $627 $500 Not Implemented
SD0241 # 01 Y:2000 01 2000 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,946 $24,320 Implemented
SD0241 # 03 Y:2000 03 2000 REDUCE EXCESSIVE BOILER BLOWDOWN $2,831 $6,150 Implemented
BD0157 # 02 Y:2000 02 2000 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $2,952 $4,600 Not Implemented
NV0148 # 01 Y:2000 01 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $768 $1,500 Implemented
WV0183 # 06 Y:2000 06 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $14,087 $10,840 Not Implemented
WV0183 # 07 Y:2000 07 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $34,536 $10,840 Not Implemented
WV0183 # 10 Y:2000 10 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $18,683 $1,000 Implemented
TN0652 # 10 Y:1999 10 1999 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $16,210 $10,000 Not Implemented
SD0237 # 03 Y:2000 03 2000 REDUCE EXCESSIVE BOILER BLOWDOWN $688 $100 Implemented
UM0158 # 04 Y:2000 04 2000 REDUCE EXCESSIVE BOILER BLOWDOWN $11,891 $9,860 Not Implemented
UM0157 # 03 Y:2000 03 2000 REDUCE EXCESSIVE BOILER BLOWDOWN $1,224 $4,430 Implemented
GT0678 # 02 Y:1999 02 1999 REDUCE EXCESSIVE BOILER BLOWDOWN $920 $900 Not Implemented
CO0456 # 04 Y:2000 04 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $930 $1,400 n/a
UM0156 # 04 Y:2000 04 2000 REDUCE EXCESSIVE BOILER BLOWDOWN $1,813 $4,430 Not Implemented
UM0156 # 06 Y:2000 06 2000 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $7,640 $6,500 Implemented
MO0273 # 02 Y:2000 02 2000 REPLACE BOILER $35,241 $30,000 Implemented
OD0152 # 08 Y:2000 08 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $452 $1,000 Not Implemented
BD0148 # 06 Y:1999 06 1999 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $653 $644 n/a
OR0361 # 01 Y:2000 01 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $24,471 $1,200 Not Implemented
IA0239 # 05 Y:2000 05 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $3,777 $1,142 Not Implemented
BD0151 # 01 Y:2000 01 2000 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $6,104 $20,000 Not Implemented
KU0536 # 01 Y:1999 01 1999 REPLACE BOILER $10,770 $29,000 n/a