Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

230

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0174 # 01 Y:2003 01 2003 INSULATE BARE EQUIPMENT $16,235 $262 Implemented
GT0771 # 02 Y:2003 02 2003 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $17,568 $23,870 Implemented
GT0771 # 03 Y:2003 03 2003 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $882 $650 Implemented
BD0247 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $13,156 $8,080 Implemented
BD0247 # 02 Y:2003 02 2003 RECOVER WASTE HEAT FROM EQUIPMENT $13,627 $1,000 Implemented
SU0170 # 04 Y:2003 04 2003 RECOVER WASTE HEAT FROM EQUIPMENT $3,181 $47 Implemented
NC0270 # 01 Y:2003 01 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $149,890 $50,000 Implemented
BD0246 # 10 Y:2003 10 2003 INSULATE BARE EQUIPMENT $3,886 $290 Implemented
IC0069 # 05 Y:2003 05 2003 REPAIR OR REPLACE STEAM TRAPS $6,176 $341 Implemented
IC0069 # 02 Y:2003 02 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $4,983 $8,812 Implemented
GT0766 # 05 Y:2003 05 2003 REPAIR AND ELIMINATE STEAM LEAKS $5,000 $1,000 Implemented
WV0281 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $1,163 $38 Implemented
LL0178 # 07 Y:2003 07 2003 INSULATE BARE EQUIPMENT $55 $98 Implemented
OR0442 # 04 Y:2003 04 2003 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $7,900 $0 Implemented
OR0441 # 03 Y:2003 03 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $4,670 $985 Implemented
LL0177 # 04 Y:2003 04 2003 INSULATE BARE EQUIPMENT $1,253 $1,600 Implemented
OR0441 # 02 Y:2003 02 2003 SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE $18,970 $2,160 Implemented
OK0671 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $880 $318 Implemented
OK0671 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $1,789 $5,340 Implemented
OR0440 # 03 Y:2003 03 2003 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $16,500 $5,130 Implemented
OK0671 # 04 Y:2003 04 2003 INSULATE BARE EQUIPMENT $459 $863 Implemented
OR0439 # 04 Y:2003 04 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $4,500 $1,850 Implemented
OR0439 # 06 Y:2003 06 2003 OPTIMIZE OPERATION OF MULTI-STAGE VACUUM STEAM JETS $3,250 $3,000 Implemented
OK0670 # 03 Y:2003 03 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $12,292 $0 Implemented
OR0437 # 05 Y:2003 05 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $9,910 $14,200 Implemented