Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0196 # 08 Y:1998 08 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $4,198 $3,500 Not Implemented
WI0315 # 06 Y:1998 06 1998 INSULATE BARE EQUIPMENT $3,542 $1,362 Not Implemented
HO0170 # 05 Y:1998 05 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,250 $200 Not Implemented
NV0098 # 03 Y:1998 03 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $9,263 $30,000 n/a
CO0407 # 02 Y:1998 02 1998 RECOVER WASTE HEAT FROM EQUIPMENT $6,170 $8,790 Not Implemented
KU0488 # 03 Y:1998 03 1998 RECOVER WASTE HEAT FROM EQUIPMENT $4,530 $670 Implemented
NV0098 # 04 Y:1998 04 1998 INSULATE BARE EQUIPMENT $289 $416 n/a
NV0098 # 02 Y:1998 02 1998 RECOVER WASTE HEAT FROM EQUIPMENT $768 $661 n/a
KU0488 # 04 Y:1998 04 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $1,660 $1,960 Implemented
OK0539 # 03 Y:1998 03 1998 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,678 $5,722 Not Implemented
SD0190 # 04 Y:1998 04 1998 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $17,334 $8,125 Not Implemented
WV0132 # 06 Y:1998 06 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $838 $1,755 Not Implemented
DS0106 # 02 Y:1998 02 1998 REPAIR AND ELIMINATE STEAM LEAKS $1,009 $400 Implemented
SF0133 # 03 Y:1998 03 1998 INCREASE AMOUNT OF CONDENSATE RETURNED $1,152 $1,611 Implemented
WV0132 # 07 Y:1998 07 1998 RECOVER WASTE HEAT FROM EQUIPMENT $526 $470 Not Implemented
DS0106 # 01 Y:1998 01 1998 INSULATE BARE EQUIPMENT $3,231 $2,430 Implemented
ND0292 # 02 Y:1998 02 1998 INSULATE BARE EQUIPMENT $2,468 $338 Implemented
UM0111 # 03 Y:1998 03 1998 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $894 $3,212 Not Implemented
UM0111 # 05 Y:1998 05 1998 RECOVER WASTE HEAT FROM EQUIPMENT $694 $4,000 Not Implemented
WI0313 # 04 Y:1998 04 1998 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $1,667 $2,000 Implemented
SD0189 # 04 Y:1998 04 1998 USE OPTIMUM THICKNESS INSULATION $678 $219 Implemented
SF0132 # 01 Y:1998 01 1998 SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE $1,548 $488 Not Implemented
HO0168 # 04 Y:1998 04 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,473 $6,290 Not Implemented
HO0168 # 03 Y:1998 03 1998 INSULATE BARE EQUIPMENT $2,141 $755 Not Implemented
IA0188 # 02 Y:1998 02 1998 INSULATE BARE EQUIPMENT $1,584 $195 Implemented