Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,125

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BS0043 # 01 Y:2014 01 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $63,855 $15,000 Implemented
MI0268 # 01 Y:2014 01 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $139,206 $330,000 Not Implemented
BD0449 # 01 Y:2014 01 2014 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $64,237 $1,500,000 Implemented
WM0054 # 03 Y:2014 03 2014 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $2,335 $10,000 Not Implemented
MZ0157 # 04 Y:2014 04 2014 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $2,223 $17,400 Not Implemented
MI0267 # 01 Y:2014 01 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $18,615 $80,000 Implemented
OR0636 # 03 Y:2014 03 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $5,708 $7,000 Implemented
OK0889 # 02 Y:2014 02 2014 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $4,415 $7,547 Not Implemented
UD0910 # 08 Y:2014 08 2014 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $377,548 $1,083,820 Implemented
SD0488 # 01 Y:2014 01 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $7,838 $7,262 Not Implemented
WM0051 # 08 Y:2014 08 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $14,378 $3,000 Not Implemented
NC0517 # 11 Y:2014 11 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $10,806 $5,000 Not Implemented
MA0733 # 05 Y:2014 05 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,595 $13,800 Not Implemented
NC0516 # 06 Y:2014 06 2014 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,840 $8,000 Not Implemented
UD0906 # 05 Y:2014 05 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,162 $10,000 Not Implemented
CO0688 # 01 Y:2014 01 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,830 $8,050 Not Implemented
UD0905 # 01 Y:2014 01 2014 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $13,929 $0 Not Implemented
OR0631 # 01 Y:2014 01 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $11,360 $250 Implemented
MI0263 # 05 Y:2014 05 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,131 $4,980 Not Implemented
OK0882 # 11 Y:2014 11 2014 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $5,834 $6,336 Not Implemented
AM0660 # 01 Y:2014 01 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,580 $10,000 Not Implemented
CO0686 # 01 Y:2014 01 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,160 $8,890 Not Implemented
MI0261 # 01 Y:2014 01 2014 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $48,959 $119,260 Not Implemented
WV0487 # 08 Y:2014 08 2014 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $2,271 $210 Not Implemented
TT0131 # 06 Y:2014 06 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $206,605 $247,740 Not Implemented