IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

50

matching recommendations
Reset
ARC 2.722 Operation
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0174 # 03 Y:2000 03 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,307 $2,000 Not Implemented
MA0479 # 01 Y:2000 01 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,300 $3,000 Implemented
MA0480 # 04 Y:2000 04 2000 AIR CONDITION ONLY SPACE NECESSARY $10,600 $5,000 Implemented
CO0477 # 06 Y:2000 06 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $220 $150 Not Implemented
OK0606 # 02 Y:2000 02 2000 AIR CONDITION ONLY SPACE NECESSARY $291 $112 Implemented
MA0477 # 04 Y:2000 04 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,910 $0 Not Implemented
MA0472 # 05 Y:2000 05 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,589 $2,000 Implemented
MS0169 # 03 Y:2000 03 2000 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $333 $355 Not Implemented
UL0247 # 01 Y:2000 01 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,177 $1,225 Implemented
MS0168 # 05 Y:2000 05 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $28,070 $5,275 Not Implemented
NC0205 # 01 Y:2000 01 2000 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $6,613 $1,000 n/a
NV0166 # 01 Y:2000 01 2000 AIR CONDITION ONLY SPACE NECESSARY $32,352 $17,000 n/a
BD0169 # 05 Y:2000 05 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $690 $0 Implemented
KU0547 # 02 Y:2000 02 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $630 $0 Implemented
GT0698 # 07 Y:2000 07 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,235 $1,800 Implemented
OD0168 # 04 Y:2000 04 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,521 $345 Not Implemented
UF0256 # 08 Y:2000 08 2000 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $7,547 $20,000 n/a
CO0470 # 04 Y:2000 04 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $760 $1,490 Not Implemented
NC0193 # 06 Y:2000 06 2000 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $64,272 $64,142 Not Implemented
ME0290 # 03 Y:2000 03 2000 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $2,732 $1,800 Implemented
CO0468 # 01 Y:2000 01 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,550 $1,610 Implemented
GT0694 # 06 Y:2000 06 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $4,224 $8,700 Implemented
MS0161 # 03 Y:2000 03 2000 AIR CONDITION ONLY SPACE NECESSARY $6,113 $3,530 Not Implemented
ND0350 # 04 Y:2000 04 2000 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $6,036 $20 Implemented
OR0365 # 04 Y:2000 04 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $35,788 $1,690 Implemented