Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

62

matching recommendations
Reset
ARC 2.723 Hardware - Heating / Cooling
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0468 # 03 Y:2015 03 2015 USE RADIANT HEATER FOR SPOT HEATING $12,081 $30,000 Not Implemented
DL0154 # 05 Y:2015 05 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,565 $7,125 Not Implemented
MI0288 # 09 Y:2015 09 2015 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $3,903 $5,740 Not Implemented
WM0078 # 01 Y:2015 01 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $31,723 $105,982 Not Implemented
UD0938 # 09 Y:2015 09 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $807 $3,133 Not Implemented
LE0402 # 05 Y:2015 05 2015 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $1,557 $4,800 Implemented
LE0402 # 06 Y:2015 06 2015 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $6,037 $22,000 Implemented
SD0519 # 04 Y:2015 04 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,983 $16,500 Implemented
MZ0207 # 01 Y:2015 01 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,485 $27,300 Implemented
OK0924 # 03 Y:2015 03 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $309 $0 Implemented
SD0520 # 01 Y:2015 01 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $43,686 $162,100 Implemented
SU0396 # 08 Y:2015 08 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $18,009 $17,408 Implemented
SD0518 # 02 Y:2015 02 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $9,705 $25,900 Not Implemented
IA0540 # 01 Y:2015 01 2015 USE RADIANT HEATER FOR SPOT HEATING $24,230 $58,000 Not Implemented
BD0466 # 06 Y:2015 06 2015 USE RADIANT HEATER FOR SPOT HEATING $2,803 $2,200 Not Implemented
NC0549 # 07 Y:2015 07 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $15,935 $40,000 Not Implemented
SD0515 # 03 Y:2015 03 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $49,380 $151,600 Not Implemented
LE0400 # 14 Y:2015 14 2015 USE RADIANT HEATER FOR SPOT HEATING $5,902 $24,000 Implemented
LE0400 # 15 Y:2015 15 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,678 $6,940 Implemented
SD0517 # 01 Y:2015 01 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $69,718 $163,200 Implemented
SD0516 # 01 Y:2015 01 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $21,830 $48,900 Implemented
NC0547 # 12 Y:2015 12 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $231 $1,000 Implemented
AM0685 # 01 Y:2015 01 2015 USE HEAT PUMP FOR SPACE CONDITIONING $11,400 $10,770 Implemented
OK0922 # 05 Y:2015 05 2015 USE RADIANT HEATER FOR SPOT HEATING $2,132 $6,660 Not Implemented
SD0513 # 01 Y:2015 01 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $10,628 $42,560 Not Implemented