Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,665
matching recommendationsARC | 3.4 | Water Use |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ST0025 # 06 Y:1985 | 06 | 1985 | RECOVER AND REUSE COOLING WATER | $700 | $1,000 | Implemented |
OK0156 # 04 Y:1985 | 04 | 1985 | RECOVER AND REUSE COOLING WATER | $1,387 | $500 | Implemented |
TN0238 # 08 Y:1984 | 08 | 1984 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,795 | $480 | Implemented |
UD0142 # 01 Y:1984 | 01 | 1984 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $28,921 | $935 | Implemented |
ST0007 # 06 Y:1984 | 06 | 1984 | RECOVER AND REUSE COOLING WATER | $8,544 | $2,000 | Not Implemented |
UD0140 # 07 Y:1984 | 07 | 1984 | RECOVER AND REUSE COOLING WATER | $1,755 | $0 | Implemented |
KU0141 # 21 Y:1984 | 21 | 1984 | MINIMIZE WATER USAGE | $1,575 | $350 | Not Implemented |
CO0007 # 10 Y:1984 | 10 | 1984 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,029 | $25 | Implemented |
KU0137 # 01 Y:1984 | 01 | 1984 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $4,772 | $4,500 | Not Implemented |
TN0219 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,381 | $30 | Not Implemented |
TS0003 # 01 Y:1984 | 01 | 1984 | MINIMIZE WATER USAGE | $3,197 | $6 | Implemented |
GT0185 # 01 Y:1983 | 01 | 1983 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $9,050 | $1,200 | Not Implemented |
GT0185 # 02 Y:1983 | 02 | 1983 | MINIMIZE WATER USAGE | $8,324 | $3,000 | Not Implemented |
UD0075 # 04 Y:1983 | 04 | 1983 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $4,855 | $17,600 | Not Implemented |
OK0068 # 02 Y:1983 | 02 | 1983 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $508 | $295 | Not Implemented |