Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

215

matching recommendations
Reset
ARC 3.4 Water Use
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0240 # 04 Y:1999 04 1999 MINIMIZE WATER USAGE $566 $40 Implemented
OD0150 # 05 Y:1999 05 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $779 $0 Not Implemented
GT0678 # 01 Y:1999 01 1999 METER WASTE WATER $4,925 $900 Implemented
TN0650 # 07 Y:1999 07 1999 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $39,640 $30,500 Not Implemented
ME0279 # 09 Y:1999 09 1999 MINIMIZE WATER USAGE $751 $1,345 Implemented
MA0454 # 03 Y:1999 03 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $667 $2,675 Not Implemented
ND0341 # 08 Y:1999 08 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $90,862 $120,000 Not Implemented
GT0681 # 04 Y:1999 04 1999 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $1,667 $600 Not Implemented
GT0681 # 01 Y:1999 01 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $10,162 $0 Not Implemented
BD0142 # 05 Y:1999 05 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,238 $3,500 Not Implemented
KU0534 # 02 Y:1999 02 1999 MINIMIZE WATER USAGE $84,000 $22,000 Not Implemented
MA0452 # 01 Y:1999 01 1999 REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING $4,467 $7,563 Implemented
DS0150 # 06 Y:1999 06 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $626 $400 Not Implemented
NC0179 # 05 Y:1999 05 1999 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $4,315 $1,425 Implemented
GT0676 # 07 Y:1999 07 1999 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $1,295 $100 Not Implemented
GT0676 # 01 Y:1999 01 1999 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $3,081 $500 Not Implemented
UL0232 # 02 Y:1999 02 1999 RECOVER AND REUSE COOLING WATER $9,701 $446 Not Implemented
UL0232 # 03 Y:1999 03 1999 RECOVER AND REUSE COOLING WATER $56,903 $5,370 Implemented
NC0180 # 06 Y:1999 06 1999 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $15,265 $1,500 Implemented
ME0278 # 12 Y:1999 12 1999 ELIMINATE LEAKS IN WATER LINES AND VALVES $250 $100 n/a
AM0357 # 02 Y:1999 02 1999 TREAT AND REUSE RINSE WATERS $45,000 $1,200 Not Implemented
MA0451 # 07 Y:1999 07 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $500 $2,675 Not Implemented
OD0149 # 05 Y:1999 05 1999 RECOVER AND REUSE COOLING WATER $17,077 $10,098 Not Implemented
OD0149 # 04 Y:1999 04 1999 METER WASTE WATER $3,741 $4,595 Not Implemented
OD0148 # 07 Y:1999 07 1999 METER WASTE WATER $4,026 $4,595 Not Implemented