Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,494

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK1110 # 07 Y:2024 07 2024 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,681 $1,861 Implemented
AM0918 # 03 Y:2024 03 2024 REPAIR FAULTY LOUVERS AND DAMPERS $412 $3,000 n/a
UF0612 # 06 Y:2024 06 2024 INSTALL TURBULATORS $13,749 $3,750 Implemented
MS0425 # 01 Y:2024 01 2024 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $6,979 $25,000 n/a
KS2426 # 04 Y:2024 04 2024 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $383 $728 n/a
WV0658 # 09 Y:2024 09 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,325 $952 Implemented
UF0611 # 08 Y:2024 08 2024 INSTALL TURBULATORS $2,454 $3,750 Implemented
SU0549 # 07 Y:2024 07 2024 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $21,453 $15,000 Not Implemented
UD1081 # 04 Y:2024 04 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,442 $0 Implemented
MZ0358 # 06 Y:2024 06 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,666 $2,000 Implemented
OR0788 # 01 Y:2024 01 2024 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $126,866 $2,500,000 Implemented
SD0651 # 10 Y:2024 10 2024 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $30,573 $17,505 Not Implemented
UD1080 # 03 Y:2024 03 2024 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $1,555 $405 Not Implemented
SD0651 # 12 Y:2024 12 2024 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $936 $220 Not Implemented
SD0653 # 11 Y:2024 11 2024 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $275 $157 Not Implemented
WV0657 # 01 Y:2024 01 2024 REPLACE BOILER $38,907 $149,240 Not Implemented
WV0657 # 07 Y:2024 07 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,266 $1,107 Implemented
AS0574 # 03 Y:2024 03 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,135 $501 Not Implemented
MI0438 # 07 Y:2024 07 2024 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $2,582 $1,027 n/a
SD0652 # 04 Y:2024 04 2024 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,512 $688 Implemented
SD0652 # 06 Y:2024 06 2024 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $88,120 $102,485 Implemented
UD1079 # 05 Y:2024 05 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,667 $1,500 Implemented
CI0028 # 08 Y:2024 08 2024 REPLACE BOILER $1,659 $8,000 n/a
CI0028 # 06 Y:2024 06 2024 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $5,530 $11,000 n/a
TT0314 # 02 Y:2024 02 2024 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $36,167 $16,000 Implemented