Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,326
matching recommendationsARC | 2.1 | Combustion Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0148 # 09 Y:2002 | 09 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,033 | $750 | Implemented |
LE0149 # 06 Y:2002 | 06 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $886 | $750 | Implemented |
MA0524 # 01 Y:2002 | 01 | 2002 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $31,997 | $0 | Not Implemented |
CO0516 # 03 Y:2002 | 03 | 2002 | IMPROVE COMBUSTION CONTROL CAPABILITY | $44,200 | $30,000 | n/a |
IA0305 # 07 Y:2002 | 07 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,521 | $1,000 | Not Implemented |
AM0420 # 08 Y:2002 | 08 | 2002 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $2,500 | $150 | Implemented |
MS0216 # 04 Y:2002 | 04 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,900 | $2,080 | Not Implemented |
MA0522 # 03 Y:2002 | 03 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $59,990 | $26,000 | n/a |
BD0218 # 01 Y:2002 | 01 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $12,638 | $34,000 | Not Implemented |
NC0251 # 05 Y:2002 | 05 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,768 | $10,000 | Implemented |
WV0254 # 07 Y:2002 | 07 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,833 | $1,000 | Implemented |
IA0291 # 09 Y:2002 | 09 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $23,689 | $59,400 | Not Implemented |
IA0291 # 08 Y:2002 | 08 | 2002 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $7,328 | $25,016 | Implemented |
SU0141 # 02 Y:2002 | 02 | 2002 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $640,000 | $9,000,000 | Implemented |
SF0245 # 01 Y:2002 | 01 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,917 | $7,200 | Not Implemented |
SU0143 # 01 Y:2002 | 01 | 2002 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $29,798 | $32,697 | Implemented |
OR0421 # 01 Y:2002 | 01 | 2002 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $31,000 | $12,000 | Implemented |
BD0216 # 05 Y:2002 | 05 | 2002 | INSTALL AUTOMATIC STACK DAMPER | $1,359 | $1,500 | Not Implemented |
BD0216 # 07 Y:2002 | 07 | 2002 | INSTALL TURBULATORS | $813 | $1,700 | Implemented |
LE0147 # 04 Y:2002 | 04 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,478 | $750 | Implemented |
IA0301 # 07 Y:2002 | 07 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,453 | $80 | Implemented |
OR0415 # 01 Y:2002 | 01 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $24,100 | $0 | Not Implemented |
OR0415 # 02 Y:2002 | 02 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $19,686 | $63,600 | Not Implemented |
NC0246 # 03 Y:2002 | 03 | 2002 | BURN A LESS EXPENSIVE GRADE OF FUEL | $3,154 | $7,500 | Not Implemented |
SF0244 # 10 Y:2002 | 10 | 2002 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $319 | $393 | Not Implemented |