IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,326

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0183 # 07 Y:2009 07 2009 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $198 $180 Not Implemented
OR0551 # 05 Y:2009 05 2009 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $83,890 $100,800 Implemented
MI0183 # 06 Y:2009 06 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,750 $1,500 Implemented
MI0183 # 02 Y:2009 02 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $5,816 $1,280 Not Implemented
OK0783 # 07 Y:2009 07 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $18,978 $3,810 Implemented
WV0397 # 04 Y:2009 04 2009 OPERATE BOILERS ON HIGH FIRE SETTING $56,916 $80,000 Not Implemented
WV0397 # 09 Y:2009 09 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,377 $49,300 Not Implemented
WV0397 # 08 Y:2009 08 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,726 $1,000 Implemented
IA0446 # 14 Y:2009 14 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $505 $1,000 Not Implemented
IA0446 # 15 Y:2009 15 2009 DIRECT WARMEST AIR TO COMBUSTION INTAKE $333 $213 Not Implemented
WV0396 # 04 Y:2009 04 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $69,637 $1,000 Implemented
MZ0041 # 02 Y:2009 02 2009 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $60,170 $43,800 Implemented
MA0653 # 01 Y:2009 01 2009 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $110,550 $270,000 Not Implemented
MA0653 # 02 Y:2009 02 2009 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $37,210 $68,000 Not Implemented
OR0549 # 03 Y:2009 03 2009 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $28,000 $700 Not Implemented
UM0358 # 04 Y:2009 04 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,766 $1,200 Not Implemented
WV0395 # 03 Y:2009 03 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $144,811 $1,000 Implemented
SD0419 # 03 Y:2009 03 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $7,840 $10,000 Not Implemented
BD0365 # 10 Y:2009 10 2009 IMPROVE COMBUSTION CONTROL CAPABILITY $33,921 $3,500 Not Implemented
BD0365 # 11 Y:2009 11 2009 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $74,498 $10,000 Not Implemented
BD0365 # 12 Y:2009 12 2009 INSTALL TURBULATORS $49,164 $2,500 Not Implemented
OR0547 # 02 Y:2009 02 2009 KEEP BOILER TUBES CLEAN $39,218 $44,000 Implemented
OR0547 # 01 Y:2009 01 2009 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $90,740 $81,950 Not Implemented
DL0041 # 01 Y:2009 01 2009 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $29,782 $0 Not Implemented
UD0805 # 09 Y:2009 09 2009 REDUCE EXCESSIVE BOILER BLOWDOWN $5,312 $5,000 Implemented