Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

196

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0206 # 09 Y:2002 09 2002 INSTALL AUTOMATIC STACK DAMPER $1,134 $2,500 Not Implemented
BD0206 # 05 Y:2002 05 2002 DIRECT WARMEST AIR TO COMBUSTION INTAKE $3,030 $8,000 Not Implemented
BD0206 # 03 Y:2002 03 2002 INSTALL TURBULATORS $3,680 $2,150 Not Implemented
WI0415 # 04 Y:2002 04 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,616 $0 Not Implemented
UD0640 # 02 Y:2002 02 2002 BURN A LESS EXPENSIVE GRADE OF FUEL $57,385 $82,200 Implemented
MS0204 # 03 Y:2002 03 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,500 $3,763 Not Implemented
LE0130 # 04 Y:2002 04 2002 IMPROVE COMBUSTION CONTROL CAPABILITY $8,789 $1,000 Implemented
NC0229 # 01 Y:2002 01 2002 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $51,728 $50,000 Implemented
BD0205 # 03 Y:2002 03 2002 INSTALL AUTOMATIC STACK DAMPER $4,550 $5,000 Not Implemented
MS0203 # 02 Y:2002 02 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $30,947 $16,790 Implemented
NC0230 # 09 Y:2002 09 2002 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $4,254 $3,500 Implemented
MS0202 # 01 Y:2002 01 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $8,051 $5,798 Not Implemented
IC0029 # 05 Y:2002 05 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,179 $1,500 Implemented
IC0029 # 06 Y:2002 06 2002 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $36,712 $36,036 Implemented
GT0726 # 03 Y:2002 03 2002 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $13,353 $11,475 Not Implemented
UF0290 # 07 Y:2002 07 2002 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $3,259 $1,633 Not Implemented
UF0290 # 08 Y:2002 08 2002 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,947 $2,300 Not Implemented
UF0290 # 04 Y:2002 04 2002 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $18,405 $33,700 Not Implemented
UF0293 # 07 Y:2002 07 2002 MOVE BOILER TO MORE EFFICIENT LOCATION $1,449 $0 n/a
LL0128 # 01 Y:2002 01 2002 CONVERT TO OXYFUEL BURNERS $235,855 $281,796 Implemented
OK0634 # 02 Y:2002 02 2002 OPERATE BOILERS ON HIGH FIRE SETTING $2,910 $4,125 Implemented
OK0634 # 03 Y:2002 03 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,571 $6,000 Not Implemented
IA0286 # 08 Y:2002 08 2002 ADJUST BURNERS FOR EFFICIENT OPERATION $2,691 $1,000 Implemented
IA0286 # 09 Y:2002 09 2002 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,570 $3,500 Not Implemented
SF0231 # 09 Y:2002 09 2002 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $6,658 $8,500 n/a