Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

121

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0363 # 07 Y:2009 07 2009 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $17,662 $3,500 Not Implemented
UA0038 # 06 Y:2009 06 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $1,493 $6,000 Not Implemented
BD0359 # 07 Y:2009 07 2009 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $2,175 $3,000 Not Implemented
OK0776 # 07 Y:2009 07 2009 OPERATE BOILERS ON HIGH FIRE SETTING $6,763 $20,340 Not Implemented
BD0358 # 06 Y:2009 06 2009 REPLACE BOILER $9,256 $601 Implemented
SF0375 # 04 Y:2009 04 2009 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $26,893 $32,381 Not Implemented
SF0375 # 09 Y:2009 09 2009 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,842 $12,018 Implemented
SF0374 # 02 Y:2009 02 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,699 $0 Implemented
SF0374 # 15 Y:2009 15 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,809 $31,988 Not Implemented
SF0374 # 03 Y:2009 03 2009 REDUCE EXCESSIVE BOILER BLOWDOWN $10,627 $2,372 Implemented
DL0037 # 04 Y:2009 04 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $1,500 $880 Not Implemented
SF0374 # 18 Y:2009 18 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $16,622 $86,476 Implemented
UF0420 # 06 Y:2009 06 2009 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $21,915 $607 Not Implemented
OK0775 # 07 Y:2009 07 2009 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $5,419 $386 Not Implemented
DL0035 # 04 Y:2009 04 2009 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $28,800 $44,500 Not Implemented
DL0035 # 01 Y:2009 01 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $70,852 $10,000 Not Implemented
UD0796 # 10 Y:2009 10 2009 INSTALL AUTOMATIC STACK DAMPER $418 $400 Implemented
WV0389 # 09 Y:2009 09 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,740 $600 Implemented
NC0388 # 02 Y:2009 02 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $400 $10,000 Implemented
UM0352 # 09 Y:2009 09 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,944 $1,200 Implemented
WV0388 # 13 Y:2009 13 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $246 $400 Not Implemented
UM0350 # 08 Y:2009 08 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $649 $1,200 Implemented
LE0284 # 06 Y:2009 06 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,526 $8,000 Not Implemented
UW0026 # 02 Y:2009 02 2009 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $93,152 $13,100 Not Implemented
DL0033 # 04 Y:2009 04 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,737 $10,000 Implemented