IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,476

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0211 # 06 Y:2001 06 2001 REPLACE BOILER $18,515 $22,255 Implemented
GT0707 # 01 Y:2001 01 2001 KEEP BOILER TUBES CLEAN $5,290 $3,000 Not Implemented
BD0181 # 07 Y:2001 07 2001 INSTALL TURBULATORS $599 $1,700 Not Implemented
SD0268 # 01 Y:2001 01 2001 MOVE BOILER TO MORE EFFICIENT LOCATION $40,607 $10,000 Not Implemented
SD0268 # 06 Y:2001 06 2001 MOVE BOILER TO MORE EFFICIENT LOCATION $10,321 $17,000 Not Implemented
OR0387 # 08 Y:2001 08 2001 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $1,885 $300 Implemented
OD0174 # 02 Y:2000 02 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $864 $1,000 Not Implemented
MA0478 # 06 Y:2000 06 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,870 $13,000 Not Implemented
OR0385 # 03 Y:2000 03 2000 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $7,231 $600 Implemented
OR0383 # 02 Y:2000 02 2000 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $114,832 $600 Implemented
OR0382 # 01 Y:2000 01 2000 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $26,817 $900 Implemented
BD0173 # 01 Y:2000 01 2000 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $31,116 $16,000 n/a
BD0172 # 05 Y:2000 05 2000 INSTALL TURBULATORS $370 $800 Not Implemented
OR0381 # 02 Y:2000 02 2000 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $699 $300 Implemented
GT0700 # 03 Y:2000 03 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $170 $0 Implemented
WI0383 # 03 Y:2000 03 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,946 $22,500 Implemented
GT0699 # 04 Y:2000 04 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,198 $1,000 n/a
UM0171 # 03 Y:2000 03 2000 REDUCE EXCESSIVE BOILER BLOWDOWN $2,065 $4,430 Not Implemented
KU0546 # 04 Y:2000 04 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,500 $1,000 Implemented
IA0257 # 02 Y:2000 02 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,420 $254 Not Implemented
OD0168 # 03 Y:2000 03 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $319 $250 Implemented
IA0250 # 01 Y:2000 01 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,769 $593 Not Implemented
IA0250 # 02 Y:2000 02 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $682 $1,400 Implemented
IA0251 # 08 Y:2000 08 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,408 $1,400 Not Implemented
IA0254 # 07 Y:2000 07 2000 DIRECT WARMEST AIR TO COMBUSTION INTAKE $316 $78 Not Implemented