Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

96

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0328 # 01 Y:2007 01 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,110 $1,000 Implemented
NC0366 # 03 Y:2007 03 2007 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $18,013 $60,000 Not Implemented
UM0327 # 05 Y:2007 05 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,516 $1,000 Implemented
UM0326 # 01 Y:2007 01 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $26,782 $1,000 Not Implemented
IC0131 # 16 Y:2007 16 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $32 $1 Implemented
WV0362 # 03 Y:2007 03 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,679 $2,000 Not Implemented
OR0520 # 06 Y:2007 06 2007 REPLACE BOILER $4,900 $5,250 Implemented
GT0838 # 04 Y:2007 04 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,908 $0 Not Implemented
GT0838 # 06 Y:2007 06 2007 REDUCE EXCESSIVE BOILER BLOWDOWN $1,288 $3,975 Not Implemented
GT0837 # 04 Y:2007 04 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $47,920 $0 Implemented
UM0323 # 10 Y:2007 10 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,122 $1,000 Implemented
TT0008 # 05 Y:2007 05 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,000 $1,500 Not Implemented
UM0322 # 05 Y:2007 05 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,439 $1,000 Implemented
CO0604 # 02 Y:2007 02 2007 DIRECT WARMEST AIR TO COMBUSTION INTAKE $112,000 $18,430 Not Implemented
OK0749 # 02 Y:2007 02 2007 REDUCE EXCESSIVE BOILER BLOWDOWN $66,275 $21,000 Not Implemented
OK0749 # 08 Y:2007 08 2007 OPERATE BOILERS ON HIGH FIRE SETTING $238,762 $50,000 Not Implemented
OK0749 # 01 Y:2007 01 2007 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $74,106 $206,725 Not Implemented
MZ0008 # 02 Y:2007 02 2007 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $44,772 $6,399 Implemented
UM0321 # 04 Y:2007 04 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,307 $1,000 Implemented
WV0361 # 04 Y:2007 04 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,204 $2,000 Implemented
MS0318 # 06 Y:2007 06 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $587 $0 Implemented
OK0748 # 04 Y:2007 04 2007 OPERATE BOILERS ON HIGH FIRE SETTING $22,448 $2,495 Implemented
TT0004 # 03 Y:2007 03 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,491 $0 Implemented
MZ0004 # 01 Y:2007 01 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,138 $2,230 Implemented
CO0601 # 04 Y:2007 04 2007 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,240 $230 Not Implemented