IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,769

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0261 # 06 Y:2000 06 2000 INSULATE BARE EQUIPMENT $2,774 $690 Implemented
MA0472 # 07 Y:2000 07 2000 INSTALL / REPAIR INSULATION ON STEAM LINES $1,195 $3,000 Implemented
MA0472 # 08 Y:2000 08 2000 INSTALL / REPAIR INSULATION ON STEAM LINES $1,064 $3,000 Implemented
SD0246 # 03 Y:2000 03 2000 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $3,276 $3,000 Implemented
WV0205 # 04 Y:2000 04 2000 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,568 $3,000 Implemented
WV0205 # 09 Y:2000 09 2000 USE OPTIMUM THICKNESS INSULATION $171 $375 Implemented
UM0174 # 04 Y:2000 04 2000 RECOVER WASTE HEAT FROM EQUIPMENT $1,038 $500 Implemented
BD0171 # 07 Y:2000 07 2000 COVER OPEN TANKS $206 $470 Implemented
AR0192 # 05 Y:2000 05 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $19,496 $24,000 Implemented
WV0204 # 05 Y:2000 05 2000 INSULATE BARE EQUIPMENT $12,395 $2,180 Implemented
UM0172 # 04 Y:2000 04 2000 RECOVER WASTE HEAT FROM EQUIPMENT $791 $500 Implemented
CO0473 # 06 Y:2000 06 2000 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,260 $500 Implemented
NC0198 # 05 Y:2000 05 2000 RECOVER WASTE HEAT FROM EQUIPMENT $1,845 $820 Implemented
KU0546 # 05 Y:2000 05 2000 RECOVER WASTE HEAT FROM EQUIPMENT $870 $740 Implemented
BD0168 # 02 Y:2000 02 2000 RECOVER WASTE HEAT FROM EQUIPMENT $1,966 $2,169 Implemented
GT0698 # 01 Y:2000 01 2000 INSULATE BARE EQUIPMENT $7,360 $3,240 Implemented
UM0169 # 05 Y:2000 05 2000 RECOVER WASTE HEAT FROM EQUIPMENT $2,117 $500 Implemented
KU0545 # 05 Y:2000 05 2000 RECOVER WASTE HEAT FROM EQUIPMENT $1,510 $1,770 Implemented
UD0607 # 05 Y:2000 05 2000 INSULATE BARE EQUIPMENT $1,428 $3,135 Implemented
WV0203 # 03 Y:2000 03 2000 REPAIR OR REPLACE STEAM TRAPS $735 $1,030 Implemented
WV0203 # 04 Y:2000 04 2000 INSULATE BARE EQUIPMENT $1,914 $535 Implemented
WV0203 # 05 Y:2000 05 2000 COVER OPEN TANKS $3,228 $1,336 Implemented
ND0360 # 07 Y:2000 07 2000 USE OPTIMUM TEMPERATURE $86 $20 Implemented
SF0199 # 02 Y:2000 02 2000 MODERATE COOLING TOWER OUTLET TEMPERATURE $4,250 $850 Implemented
OR0370 # 01 Y:2000 01 2000 USE OPTIMUM TEMPERATURE $27,300 $0 Implemented