Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,092

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0432 # 09 Y:2010 09 2010 CLEAN CONDENSER TUBES $1,343 $120 Not Implemented
OK0789 # 02 Y:2010 02 2010 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $20,004 $15,450 Not Implemented
UW0036 # 01 Y:2010 01 2010 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $30,860 $61,720 Not Implemented
UD0816 # 13 Y:2010 13 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,524 $0 Not Implemented
UD0816 # 09 Y:2010 09 2010 UTILIZE A LESS EXPENSIVE COOLING METHOD $15,412 $0 Implemented
UD0816 # 10 Y:2010 10 2010 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $3,601 $0 Not Implemented
WV0403 # 01 Y:2010 01 2010 UTILIZE A LESS EXPENSIVE COOLING METHOD $45,685 $55,000 Implemented
UW0041 # 02 Y:2010 02 2010 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $653 $1,306 Implemented
MA0660 # 05 Y:2010 05 2010 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $23,123 $0 Implemented
MA0659 # 03 Y:2010 03 2010 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $20,648 $35,545 Not Implemented
MA0659 # 01 Y:2010 01 2010 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $35,538 $103,290 Implemented
SF0383 # 05 Y:2010 05 2010 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,340 $20,638 Not Implemented
MA0658 # 03 Y:2010 03 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $16,037 $34,430 Not Implemented
IA0447 # 05 Y:2010 05 2010 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $6,801 $42,100 Not Implemented
UD0808 # 11 Y:2009 11 2009 MODERATE COOLING TOWER OUTLET TEMPERATURE $18,970 $20,000 Not Implemented
SD0423 # 03 Y:2009 03 2009 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $19,013 $4,062 Not Implemented
UD0809 # 18 Y:2009 18 2009 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $363 $0 Not Implemented
SD0421 # 07 Y:2009 07 2009 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $60,774 $175,800 Not Implemented
MI0186 # 01 Y:2009 01 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $160,282 $0 Implemented
MI0186 # 03 Y:2009 03 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $76,266 $28,000 Not Implemented
WV0398 # 17 Y:2009 17 2009 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $606 $60 Not Implemented
WV0398 # 16 Y:2009 16 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,732 $1,075 Not Implemented
IC0166 # 07 Y:2009 07 2009 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $3,264 $16,200 Not Implemented
UD0807 # 14 Y:2009 14 2009 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,896 $0 Not Implemented
UD0807 # 08 Y:2009 08 2009 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $22,644 $0 Not Implemented