Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

47

matching recommendations
Reset
ARC 2.262 Chillers and Refrigeration
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0467 # 02 Y:2000 02 2000 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $6,077 $4,000 Implemented
UD0599 # 03 Y:2000 03 2000 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $4,987 $20,000 Implemented
WI0378 # 05 Y:2000 05 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,844 $14,500 Not Implemented
NC0189 # 06 Y:2000 06 2000 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,905 $15,000 Not Implemented
NC0189 # 05 Y:2000 05 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,045 $600 Not Implemented
SF0191 # 03 Y:2000 03 2000 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $9,529 $32,232 Not Implemented
SD0243 # 01 Y:2000 01 2000 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $17,132 $28,575 Not Implemented
WI0371 # 07 Y:2000 07 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,030 $6,090 Not Implemented
TN0676 # 03 Y:2000 03 2000 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $6,275 $18,200 Implemented
WV0187 # 06 Y:2000 06 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $569 $300 Not Implemented
MA0458 # 05 Y:2000 05 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $757 $1,000 Implemented
WI0366 # 01 Y:2000 01 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $23,840 $71,500 Not Implemented
SD0237 # 01 Y:2000 01 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $28,985 $88,000 Implemented
WI0365 # 03 Y:2000 03 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $8,830 $26,500 Implemented
ND0345 # 05 Y:2000 05 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $913 $0 Implemented
WV0182 # 03 Y:2000 03 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,450 $1,870 Not Implemented
WV0182 # 07 Y:2000 07 2000 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $7,785 $12,000 Not Implemented
WV0182 # 04 Y:2000 04 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,200 $70 Implemented
WI0364 # 03 Y:2000 03 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $6,918 $20,750 Not Implemented
UM0153 # 01 Y:2000 01 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $4,796 $2,000 Not Implemented
WI0361 # 02 Y:2000 02 2000 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $14,677 $45,000 Not Implemented
TN0672 # 04 Y:2000 04 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $14,770 $17,800 Not Implemented