Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

74

matching recommendations
Reset
ARC 2.3 Electrical Power
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0025 # 04 Y:2002 04 2002 HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE $1,056 $0 Implemented
UU0025 # 02 Y:2002 02 2002 OPTIMIZE PLANT POWER FACTOR $3,455 $3,500 Implemented
UF0303 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $5,340 $24,092 Implemented
LL0145 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $5,861 $6,125 Implemented
LL0143 # 01 Y:2002 01 2002 OPTIMIZE PLANT POWER FACTOR $20,004 $29,820 Implemented
LL0141 # 01 Y:2002 01 2002 USE POWER DURING OFF-PEAK PERIODS $189,217 $0 Implemented
CO0504 # 01 Y:2002 01 2002 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,040 $7,000 Implemented
LL0138 # 01 Y:2002 01 2002 OPTIMIZE PLANT POWER FACTOR $115,474 $103,740 Implemented
LM0037 # 03 Y:2002 03 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,259 $1,700 Implemented
UU0022 # 02 Y:2002 02 2002 OPTIMIZE PLANT POWER FACTOR $5,007 $7,160 Implemented
LE0135 # 07 Y:2002 07 2002 OPTIMIZE PLANT POWER FACTOR $62,395 $12,000 Implemented
SF0235 # 14 Y:2002 14 2002 OPTIMIZE PLANT POWER FACTOR $4,195 $7,970 Implemented
MA0511 # 01 Y:2002 01 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $38,495 $4,090 Implemented
AM0417 # 02 Y:2002 02 2002 OPTIMIZE PLANT POWER FACTOR $32,450 $24,980 Implemented
UU0021 # 04 Y:2002 04 2002 OPTIMIZE PLANT POWER FACTOR $14,706 $18,000 Implemented
OK0637 # 03 Y:2002 03 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,484 $0 Implemented
UM0214 # 02 Y:2002 02 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $142,000 $30,400 Implemented
AS0321 # 02 Y:2002 02 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $42,990 $2,700 Implemented
TA0026 # 06 Y:2002 06 2002 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $500 $0 Implemented
LM0030 # 07 Y:2002 07 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $115,143 $300 Implemented
AM0413 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $5,000 $0 Implemented
LE0131 # 02 Y:2002 02 2002 USE DEMAND CONTROLLER OR LOAD SHEDDER $11,376 $4,500 Implemented
LE0131 # 01 Y:2002 01 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $15,624 $0 Implemented
IC0031 # 06 Y:2002 06 2002 USE DEMAND CONTROLLER OR LOAD SHEDDER $21,800 $3,080 Implemented
MS0205 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $2,794 $4,590 Implemented