Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
152
matching recommendationsARC | 2.3 | Electrical Power |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0245 # 03 Y:2017 | 03 | 2017 | OPTIMIZE PLANT POWER FACTOR | $13,572 | $12,250 | Not Implemented |
MZ0245 # 05 Y:2017 | 05 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,041 | $3,300 | Not Implemented |
UF0513 # 08 Y:2017 | 08 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,095 | $5,053 | Implemented |
BS0108 # 01 Y:2017 | 01 | 2017 | OPTIMIZE PLANT POWER FACTOR | $6,587 | $25,166 | Not Implemented |
MI0324 # 11 Y:2017 | 11 | 2017 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $670 | $100 | Not Implemented |
MI0324 # 03 Y:2017 | 03 | 2017 | OPTIMIZE PLANT POWER FACTOR | $28,032 | $41,300 | Implemented |
NL0015 # 02 Y:2017 | 02 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,416 | $0 | Implemented |
AM0740 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $15,720 | $23,900 | Not Implemented |
UU0124 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $5,444 | $5,000 | Implemented |
UU0124 # 01 Y:2017 | 01 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,503 | $0 | Implemented |
UD0977 # 07 Y:2017 | 07 | 2017 | OPTIMIZE PLANT POWER FACTOR | $3,320 | $6,000 | Not Implemented |
TT0199 # 03 Y:2017 | 03 | 2017 | OPTIMIZE PLANT POWER FACTOR | $5,729 | $8,000 | Not Implemented |
UF0512 # 03 Y:2017 | 03 | 2017 | OPTIMIZE PLANT POWER FACTOR | $38,189 | $13,000 | Implemented |
UF0512 # 04 Y:2017 | 04 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $23,030 | $40,000 | Not Implemented |
UF0512 # 01 Y:2017 | 01 | 2017 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $401,159 | $2,500,000 | Not Implemented |
AM0739 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $17,900 | $28,900 | Not Implemented |
TR0006 # 08 Y:2017 | 08 | 2017 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $23,655 | $0 | n/a |
UK1710 # 06 Y:2017 | 06 | 2017 | OPTIMIZE PLANT POWER FACTOR | $8,180 | $18,216 | Not Implemented |
MZ0240 # 07 Y:2017 | 07 | 2017 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $119,328 | $208,000 | Implemented |
SD0556 # 01 Y:2017 | 01 | 2017 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $57,756 | $205,000 | Implemented |
UD0976 # 01 Y:2017 | 01 | 2017 | OPTIMIZE PLANT POWER FACTOR | $2,704 | $1,000 | Not Implemented |
UK1708 # 09 Y:2017 | 09 | 2017 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $22,096 | $78,750 | Not Implemented |
LE0444 # 11 Y:2017 | 11 | 2017 | CONSIDER POWER LOSS AS WELL AS INITIAL LOADS AND LOAD GROWTH IN DOWN-SIZING TRANSFORMERS | $233,480 | $1,905,000 | Implemented |
SD0555 # 01 Y:2017 | 01 | 2017 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $18,916 | $65,600 | Not Implemented |
AM0738 # 01 Y:2017 | 01 | 2017 | OPTIMIZE PLANT POWER FACTOR | $23,860 | $39,900 | Implemented |