Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

198

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0482 # 04 Y:2001 04 2001 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $990 $370 Implemented
LE0106 # 06 Y:2001 06 2001 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $6,293 $41,225 Not Implemented
UD0616 # 08 Y:2001 08 2001 INSTALL TIMERS AND/OR THERMOSTATS $495 $1,200 Not Implemented
LE0104 # 01 Y:2001 01 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,815 $1,500 Not Implemented
BD0182 # 02 Y:2001 02 2001 USE RADIANT HEATER FOR SPOT HEATING $25,600 $45,600 Not Implemented
MA0483 # 06 Y:2001 06 2001 USE RADIANT HEATER FOR SPOT HEATING $1,050 $6,000 Not Implemented
MS0180 # 06 Y:2001 06 2001 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $2,093 $1,573 Not Implemented
MS0180 # 02 Y:2001 02 2001 INSTALL TIMERS AND/OR THERMOSTATS $2,283 $1,063 Not Implemented
TA0001 # 03 Y:2001 03 2001 USE RADIANT HEATER FOR SPOT HEATING $2,125 $417 Not Implemented
LL0103 # 01 Y:2001 01 2001 INSTALL TIMERS AND/OR THERMOSTATS $597 $294 Not Implemented
WI0390 # 07 Y:2001 07 2001 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $481 $0 Implemented
SF0212 # 05 Y:2001 05 2001 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION $18,923 $15,000 Not Implemented
MA0482 # 03 Y:2001 03 2001 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $8,590 $30,000 Not Implemented
MA0482 # 05 Y:2001 05 2001 USE RADIANT HEATER FOR SPOT HEATING $5,430 $25,000 Not Implemented
NC0210 # 06 Y:2001 06 2001 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $60,672 $400,000 Not Implemented
NC0210 # 05 Y:2001 05 2001 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $31,927 $70,000 Not Implemented
SU0102 # 03 Y:2001 03 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $758 $1,323 Implemented
AM0390 # 04 Y:2001 04 2001 USE RADIANT HEATER FOR SPOT HEATING $19,350 $4,700 Not Implemented
UD0612 # 06 Y:2001 06 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $528 $600 Not Implemented
UD0612 # 03 Y:2001 03 2001 INSTALL TIMERS AND/OR THERMOSTATS $782 $800 Implemented
WI0389 # 02 Y:2001 02 2001 INSTALL TIMERS AND/OR THERMOSTATS $1,900 $1,000 Implemented
SU0101 # 03 Y:2001 03 2001 AIR CONDITION ONLY SPACE NECESSARY $176 $253 Not Implemented
AS0295 # 02 Y:2001 02 2001 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,459 $10,800 Not Implemented
MS0179 # 04 Y:2001 04 2001 INSTALL TIMERS AND/OR THERMOSTATS $454 $236 Not Implemented
CO0481 # 03 Y:2001 03 2001 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,230 $880 Implemented