Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,326
matching recommendationsARC | 2.1 | Combustion Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0255 # 07 Y:2004 | 07 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,586 | $2,000 | Not Implemented |
CO0539 # 03 Y:2004 | 03 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $3,300 | $5,180 | Implemented |
WI0463 # 02 Y:2004 | 02 | 2004 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $17,690 | $17,690 | Not Implemented |
SD0333 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,979 | $15,000 | Not Implemented |
SF0278 # 04 Y:2004 | 04 | 2004 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $1,624 | $1,887 | n/a |
SF0278 # 06 Y:2004 | 06 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $1,847 | $3,074 | n/a |
MI0074 # 06 Y:2004 | 06 | 2004 | KEEP BOILER TUBES CLEAN | $18,447 | $30,050 | Implemented |
NC0279 # 01 Y:2004 | 01 | 2004 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $3,220 | $20,000 | Implemented |
AS0372 # 04 Y:2004 | 04 | 2004 | BURN A LESS EXPENSIVE GRADE OF FUEL | $170,924 | $52,200 | Not Implemented |
NC0279 # 05 Y:2004 | 05 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,880 | $9,200 | Not Implemented |
OK0680 # 04 Y:2004 | 04 | 2004 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $19,697 | $15,783 | n/a |
MS0245 # 03 Y:2004 | 03 | 2004 | REPLACE BOILER | $6,523 | $4,642 | Not Implemented |
MA0547 # 10 Y:2004 | 10 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,829 | $7,475 | Not Implemented |
WI0462 # 05 Y:2004 | 05 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,319 | $500 | Not Implemented |
GT0778 # 06 Y:2004 | 06 | 2004 | CONTROL PRESSURE ON STEAMER OPERATIONS | $5,788 | $13,000 | Not Implemented |
UF0337 # 01 Y:2004 | 01 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $309,508 | $180,000 | Not Implemented |
IC0076 # 02 Y:2004 | 02 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,524 | $49,376 | Implemented |
LE0181 # 02 Y:2004 | 02 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $37,431 | $2,000 | Implemented |
LE0181 # 03 Y:2004 | 03 | 2004 | USE STEAM SPARGING OR INJECTIONS IN PLACE OF INDIRECT HEATING | $5,226 | $10,000 | Not Implemented |
IA0336 # 03 Y:2004 | 03 | 2004 | REPLACE BOILER | $27,684 | $150,000 | Implemented |
IA0336 # 01 Y:2004 | 01 | 2004 | REDUCE EXCESSIVE BOILER BLOWDOWN | $3,854 | $4,300 | Implemented |
LE0179 # 05 Y:2004 | 05 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $960 | $750 | Not Implemented |
GT0777 # 08 Y:2004 | 08 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $13,327 | $20,670 | n/a |
GT0776 # 10 Y:2004 | 10 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,120 | $16,200 | n/a |
GT0776 # 11 Y:2004 | 11 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $18,496 | $100,000 | n/a |