Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
174
matching recommendationsARC | 2.1 | Combustion Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0421 # 07 Y:2007 | 07 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $1,093 | $1,800 | Implemented |
IA0419 # 01 Y:2007 | 01 | 2007 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $4,302 | $1,140 | Not Implemented |
DL0010 # 02 Y:2007 | 02 | 2007 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $9,440 | $2,500 | Not Implemented |
DL0010 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,529 | $450 | Implemented |
BD0338 # 06 Y:2007 | 06 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $369,530 | $30,001 | Not Implemented |
BD0338 # 07 Y:2007 | 07 | 2007 | REPLACE BOILER | $36,792 | $110,001 | Implemented |
MI0158 # 10 Y:2007 | 10 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,886 | $2,000 | Implemented |
MA0626 # 02 Y:2007 | 02 | 2007 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $6,543 | $8,000 | Not Implemented |
DL0009 # 03 Y:2007 | 03 | 2007 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $11,200 | $60,000 | Not Implemented |
IA0416 # 05 Y:2007 | 05 | 2007 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,251 | $1,500 | Not Implemented |
UW0009 # 05 Y:2007 | 05 | 2007 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $11,196 | $2,080 | Not Implemented |
UW0009 # 06 Y:2007 | 06 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $4,114 | $3,000 | Not Implemented |
SF0349 # 07 Y:2007 | 07 | 2007 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,644 | $8,646 | Not Implemented |
BD0334 # 02 Y:2007 | 02 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $210,390 | $615,001 | Not Implemented |
MA0624 # 05 Y:2007 | 05 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $12,255 | $75,000 | Implemented |
UM0333 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,901 | $2,000 | Implemented |
UM0332 # 02 Y:2007 | 02 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $56,464 | $1,000 | Implemented |
GT0844 # 01 Y:2007 | 01 | 2007 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $19,992 | $28,800 | Not Implemented |
GT0844 # 02 Y:2007 | 02 | 2007 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $35,650 | $40,000 | Not Implemented |
GT0844 # 04 Y:2007 | 04 | 2007 | REDUCE EXCESSIVE BOILER BLOWDOWN | $44,955 | $10,000 | Not Implemented |
GT0844 # 03 Y:2007 | 03 | 2007 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $71,952 | $14,867 | Not Implemented |
IA0415 # 05 Y:2007 | 05 | 2007 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,262 | $1,500 | Implemented |
UD0769 # 08 Y:2007 | 08 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $23,200 | $400 | Implemented |
UD0769 # 09 Y:2007 | 09 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $13,400 | $600 | Not Implemented |
BD0333 # 03 Y:2007 | 03 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $36,206 | $15,001 | Not Implemented |