Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,767
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0386 # 02 Y:2014 | 02 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $61,300 | $2,592 | Implemented |
LE0386 # 06 Y:2014 | 06 | 2014 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $12,502 | $16,700 | Implemented |
OR0636 # 03 Y:2014 | 03 | 2014 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $5,708 | $7,000 | Implemented |
OK0896 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,653 | $1,751 | Implemented |
NC0524 # 11 Y:2014 | 11 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $1,126 | $1,050 | Implemented |
NC0526 # 02 Y:2014 | 02 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,271 | $2,400 | Implemented |
UK1405 # 04 Y:2014 | 04 | 2014 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $32,296 | $39,600 | Implemented |
UK1405 # 06 Y:2014 | 06 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $27,426 | $2,678 | Implemented |
UK1405 # 09 Y:2014 | 09 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,146 | $1,540 | Implemented |
UK1405 # 12 Y:2014 | 12 | 2014 | INSULATE FEEDWATER TANK | $3,480 | $1,769 | Implemented |
OK0889 # 09 Y:2014 | 09 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,124 | $239 | Implemented |
UD0910 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,400 | $10,000 | Implemented |
UD0910 # 08 Y:2014 | 08 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $377,548 | $1,083,820 | Implemented |
IA0525 # 06 Y:2014 | 06 | 2014 | INSULATE BARE EQUIPMENT | $3,951 | $100 | Implemented |
SU0365 # 06 Y:2014 | 06 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,723 | $4,216 | Implemented |
MA0735 # 02 Y:2014 | 02 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,745 | $3,519 | Implemented |
IA0524 # 06 Y:2014 | 06 | 2014 | USE OPTIMUM TEMPERATURE | $660 | $20 | Implemented |
UA0127 # 08 Y:2014 | 08 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,469 | $40,000 | Implemented |
UA0127 # 09 Y:2014 | 09 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $220 | $790 | Implemented |
NC0519 # 03 Y:2014 | 03 | 2014 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $104,811 | $52,500 | Implemented |
NC0519 # 04 Y:2014 | 04 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $21,819 | $2,200 | Implemented |
WV0495 # 06 Y:2014 | 06 | 2014 | INSULATE BARE EQUIPMENT | $5,177 | $5,764 | Implemented |
WV0494 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,592 | $1,010 | Implemented |
BS0037 # 01 Y:2014 | 01 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $108 | $540 | Implemented |
BS0037 # 07 Y:2014 | 07 | 2014 | ISOLATE HOT OR COLD EQUIPMENT | $26 | $21 | Implemented |