Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

603

matching recommendations
Reset
ARC 2.261 Cooling Towers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0060 # 02 Y:2011 02 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $804 $2,040 Not Implemented
SD0507 # 05 Y:2011 05 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,758 $7,385 Not Implemented
MA0668 # 03 Y:2011 03 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,401 $11,610 Implemented
TT0063 # 06 Y:2011 06 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $12,516 $4,000 Not Implemented
IA0462 # 08 Y:2011 08 2011 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $22,774 $1,500 Not Implemented
MA0667 # 03 Y:2011 03 2011 MODERATE COOLING TOWER OUTLET TEMPERATURE $11,694 $10,590 Implemented
MA0667 # 07 Y:2011 07 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,047 $17,500 Not Implemented
SD0431 # 04 Y:2011 04 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $817 $2,000 Not Implemented
UD0828 # 13 Y:2010 13 2010 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $16,653 $25 Implemented
DL0060 # 01 Y:2010 01 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $65,458 $79,125 Not Implemented
LL0335 # 07 Y:2010 07 2010 MODERATE COOLING TOWER OUTLET TEMPERATURE $553 $467 Not Implemented
LE0305 # 06 Y:2010 06 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $12,566 $35,000 Not Implemented
OK0793 # 05 Y:2010 05 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $104,850 $134,480 Not Implemented
NC0407 # 01 Y:2010 01 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,128 $60,000 Implemented
WV0409 # 10 Y:2010 10 2010 MODERATE COOLING TOWER OUTLET TEMPERATURE $1,165 $400 Not Implemented
UA0054 # 05 Y:2010 05 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $42,638 $40,400 Not Implemented
GT0873 # 02 Y:2010 02 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $10,144 $4,600 Not Implemented
MA0663 # 03 Y:2010 03 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,990 $21,410 Not Implemented
TT0049 # 06 Y:2010 06 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $10,723 $0 Not Implemented
UF0432 # 09 Y:2010 09 2010 CLEAN CONDENSER TUBES $1,343 $120 Not Implemented
UD0816 # 13 Y:2010 13 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,524 $0 Not Implemented
MA0658 # 03 Y:2010 03 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $16,037 $34,430 Not Implemented
SD0423 # 03 Y:2009 03 2009 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $19,013 $4,062 Not Implemented
UD0808 # 11 Y:2009 11 2009 MODERATE COOLING TOWER OUTLET TEMPERATURE $18,970 $20,000 Not Implemented
UD0807 # 08 Y:2009 08 2009 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $22,644 $0 Not Implemented