Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

64

matching recommendations
Reset
ARC 2.3 Electrical Power
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0523 # 01 Y:1997 01 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $34,683 $0 Implemented
UD0521 # 01 Y:1997 01 1997 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,099 $0 Implemented
UF0181 # 05 Y:1997 05 1997 OPTIMIZE PLANT POWER FACTOR $5,604 $6,445 Implemented
WI0300 # 11 Y:1997 11 1997 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $585 $0 Implemented
HO0158 # 03 Y:1997 03 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,827 $0 Implemented
MS0087 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $5,870 $1,500 Implemented
DS0095 # 04 Y:1997 04 1997 OPTIMIZE PLANT POWER FACTOR $1,824 $2,094 Implemented
AM0302 # 08 Y:1997 08 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $210 $0 Implemented
UD0519 # 04 Y:1997 04 1997 USE DEMAND CONTROLLER OR LOAD SHEDDER $811 $0 Implemented
IA0166 # 09 Y:1997 09 1997 OPTIMIZE PLANT POWER FACTOR $1,096 $4,700 Implemented
DS0093 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $802 $1,500 Implemented
ND0274 # 02 Y:1997 02 1997 OPTIMIZE PLANT POWER FACTOR $10,153 $15,462 Implemented
MS0086 # 03 Y:1997 03 1997 OPTIMIZE PLANT POWER FACTOR $1,998 $1,500 Implemented
ND0272 # 09 Y:1997 09 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,544 $8,000 Implemented
AM0301 # 03 Y:1997 03 1997 OPTIMIZE PLANT POWER FACTOR $1,600 $1,750 Implemented
AM0301 # 02 Y:1997 02 1997 OPTIMIZE PLANT POWER FACTOR $2,930 $3,040 Implemented
AM0301 # 04 Y:1997 04 1997 OPTIMIZE PLANT POWER FACTOR $1,000 $1,085 Implemented
UF0176 # 04 Y:1997 04 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,726 $0 Implemented
MS0085 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $9,330 $5,625 Implemented
SF0116 # 03 Y:1997 03 1997 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $190 $0 Implemented
AR0114 # 07 Y:1997 07 1997 OPTIMIZE PLANT POWER FACTOR $21,464 $15,300 Implemented
DS0089 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $7,041 $1,750 Implemented
ND0269 # 01 Y:1997 01 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $144,546 $20,000 Implemented
AM0297 # 03 Y:1997 03 1997 OPTIMIZE PLANT POWER FACTOR $21,900 $22,340 Implemented
WV0115 # 07 Y:1997 07 1997 USE DEMAND CONTROLLER OR LOAD SHEDDER $23,639 $5,000 Implemented