Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,859

matching recommendations
Reset
ARC 2.3 Electrical Power
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0500 # 01 Y:2005 01 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $57,577 $25,000 n/a
CO0577 # 01 Y:2005 01 2005 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $141,620 $513,000 Not Implemented
UM0290 # 05 Y:2005 05 2005 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,242 $0 Not Implemented
LE0222 # 04 Y:2005 04 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,048 $2,000 Not Implemented
LE0224 # 10 Y:2005 10 2005 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $4,055 $520 Not Implemented
LE0218 # 02 Y:2005 02 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,740 $3,000 Not Implemented
UU0088 # 06 Y:2005 06 2005 OPTIMIZE PLANT POWER FACTOR $15,260 $13,990 Not Implemented
UU0091 # 05 Y:2005 05 2005 OPTIMIZE PLANT POWER FACTOR $12,500 $15,290 Not Implemented
UU0091 # 01 Y:2005 01 2005 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,270 $7,000 Not Implemented
LE0225 # 04 Y:2005 04 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,707 $200 Implemented
LE0223 # 04 Y:2005 04 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,831 $2,500 Implemented
OR0492 # 09 Y:2005 09 2005 OPTIMIZE PLANT POWER FACTOR $2,200 $10,000 Implemented
OR0491 # 08 Y:2005 08 2005 OPTIMIZE PLANT POWER FACTOR $650 $1,800 Not Implemented
OK0717 # 02 Y:2005 02 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,162 $7,760 Not Implemented
CO0576 # 02 Y:2005 02 2005 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $4,450 $0 Not Implemented
OR0490 # 08 Y:2005 08 2005 OPTIMIZE PLANT POWER FACTOR $2,750 $5,600 Not Implemented
NC0324 # 04 Y:2005 04 2005 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $1,571 $5,425 Not Implemented
TA0102 # 01 Y:2005 01 2005 USE POWER DURING OFF-PEAK PERIODS $20,445 $0 Implemented
UD0730 # 09 Y:2005 09 2005 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $3,480 $1,500 Not Implemented
OR0489 # 09 Y:2005 09 2005 OPTIMIZE PLANT POWER FACTOR $2,090 $5,200 Not Implemented
OR0488 # 02 Y:2005 02 2005 OPTIMIZE PLANT POWER FACTOR $680 $2,000 Not Implemented
CO0575 # 02 Y:2005 02 2005 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $62,190 $230,000 Not Implemented
OK0716 # 01 Y:2005 01 2005 OPTIMIZE PLANT POWER FACTOR $10,863 $38,544 Not Implemented
SD0371 # 08 Y:2005 08 2005 USE POWER DURING OFF-PEAK PERIODS $31,048 $0 Not Implemented
BD0293 # 05 Y:2005 05 2005 USE POWER DURING OFF-PEAK PERIODS $950 $1,700 Implemented