Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,845

matching recommendations
Reset
ARC 2.3 Electrical Power
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0815 # 02 Y:2020 02 2020 USE EXISTING DAM TO GENERATE ELECTRICITY $33,419 $150,000 Not Implemented
AS0481 # 01 Y:2020 01 2020 USE POWER DURING OFF-PEAK PERIODS $7,396 $298 Implemented
UU0163 # 04 Y:2020 04 2020 OPTIMIZE PLANT POWER FACTOR $4,707 $8,012 Not Implemented
UU0163 # 01 Y:2020 01 2020 USE EXISTING DAM TO GENERATE ELECTRICITY $38,699 $100,000 Not Implemented
MZ0275 # 04 Y:2020 04 2020 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,201 $3,250 Not Implemented
UF0549 # 01 Y:2020 01 2020 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $737,260 $2,600,000 Not Implemented
WV0590 # 10 Y:2020 10 2020 OPTIMIZE PLANT POWER FACTOR $2,899 $8,000 Not Implemented
GT0942 # 06 Y:2020 06 2020 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $113,048 $690,000 Not Implemented
CL2004 # 02 Y:2020 02 2020 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $79,699 $350,000 Implemented
UA0222 # 02 Y:2020 02 2020 OPTIMIZE PLANT POWER FACTOR $12,593 $6,955 Not Implemented
MA0813 # 04 Y:2020 04 2020 OPTIMIZE PLANT POWER FACTOR $4,535 $8,890 Not Implemented
TT0233 # 03 Y:2020 03 2020 OPTIMIZE PLANT POWER FACTOR $43,091 $147,540 Implemented
UD1012 # 10 Y:2020 10 2020 OPTIMIZE PLANT POWER FACTOR $145,150 $100,000 Not Implemented
AM0798 # 02 Y:2020 02 2020 OPTIMIZE PLANT POWER FACTOR $126,730 $229,415 Implemented
NL0045 # 04 Y:2020 04 2020 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $967 $672 Not Implemented
TR0022 # 01 Y:2020 01 2020 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,078 $0 Not Implemented
WV0589 # 05 Y:2020 05 2020 OPTIMIZE PLANT POWER FACTOR $10,950 $36,000 Implemented
OK1023 # 03 Y:2020 03 2020 OPTIMIZE PLANT POWER FACTOR $464 $1,236 Not Implemented
TT0235 # 03 Y:2020 03 2020 OPTIMIZE PLANT POWER FACTOR $24,204 $32,000 Not Implemented
AM0797 # 01 Y:2020 01 2020 OPTIMIZE PLANT POWER FACTOR $17,410 $34,210 Implemented
MI0368 # 06 Y:2020 06 2020 OPTIMIZE PLANT POWER FACTOR $2,326 $1,672 Implemented
AM0796 # 02 Y:2020 02 2020 OPTIMIZE PLANT POWER FACTOR $20,000 $47,510 Not Implemented
NC0647 # 04 Y:2020 04 2020 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $20,880 $5,000 Not Implemented
NC0647 # 05 Y:2020 05 2020 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $124,057 $600,000 Not Implemented
LE0488 # 03 Y:2020 03 2020 REPLACE DC EQUIPMENT WITH AC EQUIPMENT $82,690 $150,334 Implemented