Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

132

matching recommendations
Reset
ARC 2.3 Electrical Power
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0415 # 01 Y:2012 01 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $77,652 $5,000 Not Implemented
SF0415 # 02 Y:2012 02 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,634 $8,163 Implemented
SF0415 # 09 Y:2012 09 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $95,167 $0 Implemented
UD0855 # 01 Y:2012 01 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $23,100 $0 Implemented
WM0001 # 03 Y:2012 03 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $488 $0 Not Implemented
UA0082 # 09 Y:2012 09 2012 OPTIMIZE PLANT POWER FACTOR $18,443 $21,400 Not Implemented
AM0611 # 04 Y:2012 04 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,110 $2,500 Not Implemented
AM0611 # 10 Y:2012 10 2012 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $180 $0 Not Implemented
BD0413 # 08 Y:2012 08 2012 USE POWER DURING OFF-PEAK PERIODS $555 $20 Not Implemented
MZ0083 # 01 Y:2012 01 2012 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $2,727 $16,800 Not Implemented
TT0088 # 02 Y:2012 02 2012 OPTIMIZE PLANT POWER FACTOR $1,465 $3,978 Not Implemented
WV0446 # 14 Y:2012 14 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,403 $5,700 Not Implemented
WV0446 # 01 Y:2012 01 2012 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $147,469 $548,000 Not Implemented
BD0412 # 07 Y:2012 07 2012 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $798 $40 Not Implemented
MZ0080 # 05 Y:2012 05 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $12,554 $0 Not Implemented
MZ0081 # 05 Y:2012 05 2012 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $58,850 $120,000 Implemented
WV0445 # 04 Y:2012 04 2012 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $10,469 $0 Implemented
SD0449 # 08 Y:2012 08 2012 OPTIMIZE PLANT POWER FACTOR $3,189 $5,775 Not Implemented
BD0411 # 04 Y:2012 04 2012 USE POWER DURING OFF-PEAK PERIODS $845 $10 Not Implemented
AM0610 # 04 Y:2012 04 2012 OPTIMIZE PLANT POWER FACTOR $6,000 $13,190 Not Implemented
SU0319 # 09 Y:2012 09 2012 OPTIMIZE PLANT POWER FACTOR $21,253 $79,288 Not Implemented
SD0448 # 05 Y:2012 05 2012 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $92,055 $415,000 Implemented
MZ0078 # 07 Y:2012 07 2012 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $9,573 $9,800 Not Implemented
IP0001 # 01 Y:2012 01 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $75,906 $0 Not Implemented
MZ0078 # 04 Y:2012 04 2012 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS $10,070 $0 Implemented