Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

196

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0715 # 08 Y:2005 08 2005 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $5,361 $26,590 Not Implemented
UD0727 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,196 $15,000 Implemented
SF0312 # 09 Y:2005 09 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,715 $2,450 Not Implemented
UM0289 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,576 $2,500 Implemented
UD0726 # 01 Y:2005 01 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $222,216 $3,730 Implemented
WV0323 # 03 Y:2005 03 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,575 $1,000 Not Implemented
MS0281 # 01 Y:2005 01 2005 BURN A LESS EXPENSIVE GRADE OF FUEL $79,041 $295,888 Not Implemented
UD0725 # 03 Y:2005 03 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,863 $28,350 Implemented
UD0725 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,315 $1,320 Implemented
SU0217 # 04 Y:2005 04 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,785 $500 Implemented
NC0321 # 03 Y:2005 03 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $19,559 $3,000 Implemented
IC0108 # 01 Y:2005 01 2005 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $85,726 $22,992 Not Implemented
UD0724 # 07 Y:2005 07 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,199 $7,500 Not Implemented
BD0292 # 07 Y:2005 07 2005 BURN A LESS EXPENSIVE GRADE OF FUEL $1,500 $1,400 Implemented
BD0292 # 06 Y:2005 06 2005 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $1,915 $2,680 Implemented
UD0723 # 08 Y:2005 08 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,309 $0 Implemented
UD0723 # 07 Y:2005 07 2005 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $4,573 $0 Implemented
NC0319 # 01 Y:2005 01 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $1,809 $2,000 Implemented
MI0114 # 02 Y:2005 02 2005 IMPROVE COMBUSTION CONTROL CAPABILITY $20,574 $30,050 Implemented
SD0370 # 02 Y:2005 02 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $17,581 $22,500 Not Implemented
MI0113 # 04 Y:2005 04 2005 IMPROVE COMBUSTION CONTROL CAPABILITY $5,163 $17,100 Implemented
SF0311 # 10 Y:2005 10 2005 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $3,402 $5,030 Not Implemented
SF0311 # 14 Y:2005 14 2005 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $22,029 $46,851 Not Implemented
WV0320 # 16 Y:2005 16 2005 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $351 $26 Not Implemented
IC0106 # 07 Y:2005 07 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,315 $0 Implemented