Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,433
matching recommendationsARC | 2.1 | Combustion Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0394 # 02 Y:2015 | 02 | 2015 | REPLACE BOILER | $16,261 | $75 | Not Implemented |
LE0394 # 07 Y:2015 | 07 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $734 | $1,500 | Not Implemented |
IP0037 # 08 Y:2015 | 08 | 2015 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $32,642 | $7,996 | Implemented |
UA0138 # 01 Y:2015 | 01 | 2015 | BURN A LESS EXPENSIVE GRADE OF FUEL | $27,518 | $0 | Not Implemented |
OR0646 # 01 Y:2015 | 01 | 2015 | IMPROVE COMBUSTION CONTROL CAPABILITY | $80,430 | $5,071 | Implemented |
OR0646 # 02 Y:2015 | 02 | 2015 | IMPROVE COMBUSTION CONTROL CAPABILITY | $42,592 | $25,071 | Not Implemented |
TT0157 # 10 Y:2015 | 10 | 2015 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,978 | $1,000 | Not Implemented |
WV0504 # 04 Y:2015 | 04 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,984 | $500 | Implemented |
UD0922 # 01 Y:2015 | 01 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $31,816 | $0 | Not Implemented |
SF0464 # 01 Y:2015 | 01 | 2015 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $884 | $0 | Implemented |
MA0744 # 03 Y:2015 | 03 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,413 | $39,000 | Not Implemented |
BS0049 # 03 Y:2015 | 03 | 2015 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $63,716 | $137,445 | Not Implemented |
SF0463 # 03 Y:2015 | 03 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,452 | $0 | Implemented |
SF0462 # 04 Y:2015 | 04 | 2015 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,104 | $1,941 | Implemented |
SF0462 # 06 Y:2015 | 06 | 2015 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $601 | $1,000 | Not Implemented |
OK0908 # 03 Y:2015 | 03 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $621 | $432 | Implemented |
DL0142 # 04 Y:2015 | 04 | 2015 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $21,578 | $5,310 | Implemented |
UK1502 # 11 Y:2015 | 11 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,775 | $1,000 | Not Implemented |
UA0136 # 02 Y:2015 | 02 | 2015 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $15,296 | $22,500 | Not Implemented |
WV0503 # 04 Y:2015 | 04 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,899 | $500 | Implemented |
WV0502 # 08 Y:2015 | 08 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,826 | $500 | Implemented |
WV0501 # 01 Y:2015 | 01 | 2015 | IMPROVE COMBUSTION CONTROL CAPABILITY | $12,166 | $24,000 | Not Implemented |
UD0921 # 03 Y:2015 | 03 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $723 | $0 | Not Implemented |
MI0274 # 03 Y:2015 | 03 | 2015 | BURN A LESS EXPENSIVE GRADE OF FUEL | $10,584 | $14,880 | Not Implemented |
SF0461 # 07 Y:2015 | 07 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $424 | $2,004 | Not Implemented |