Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

25

matching recommendations
Reset
ARC 2.11 FURNACES, OVENS AND DIRECTLY FIRED OPERATIONS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0562 # 01 Y:1998 01 1998 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $14,801 $1,936 Implemented
BD0125 # 01 Y:1998 01 1998 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $38,905 $106,500 Not Implemented
MA0419 # 03 Y:1998 03 1998 ADJUST BURNERS FOR EFFICIENT OPERATION $36,192 $201,500 Not Implemented
AS0229 # 09 Y:1998 09 1998 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,718 $450 Implemented
OR0326 # 05 Y:1998 05 1998 ADJUST BURNERS FOR EFFICIENT OPERATION $1,680 $405 Not Implemented
OR0325 # 03 Y:1998 03 1998 ADJUST BURNERS FOR EFFICIENT OPERATION $4,674 $0 Implemented
OR0325 # 01 Y:1998 01 1998 ADJUST BURNERS FOR EFFICIENT OPERATION $5,486 $500 Not Implemented
WV0145 # 03 Y:1998 03 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,936 $1,000 Implemented
WV0145 # 17 Y:1998 17 1998 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $1,559 $570 Not Implemented
SD0208 # 02 Y:1998 02 1998 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $36,215 $3,000 Not Implemented
SD0208 # 03 Y:1998 03 1998 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $10,888 $2,500 Not Implemented
UD0556 # 03 Y:1998 03 1998 ADJUST BURNERS FOR EFFICIENT OPERATION $8,037 $200 Implemented
KU0501 # 03 Y:1998 03 1998 IMPROVE COMBUSTION CONTROL CAPABILITY $2,960 $10,890 Not Implemented
ME0251 # 04 Y:1998 04 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,020 $400 Implemented
WV0149 # 14 Y:1998 14 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,046 $1,000 Not Implemented
WV0146 # 03 Y:1998 03 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,135 $1,000 Implemented
OR0321 # 02 Y:1998 02 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $8,820 $0 Not Implemented
NC0139 # 03 Y:1998 03 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $34,875 $2,500 Not Implemented
WV0141 # 06 Y:1998 06 1998 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $2,538 $470 Not Implemented
UD0544 # 06 Y:1998 06 1998 REPAIR FAULTY LOUVERS AND DAMPERS $2,092 $400 Implemented
ME0240 # 06 Y:1998 06 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $370 $400 Implemented
GT0634 # 06 Y:1998 06 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,220 $0 Implemented
NV0101 # 04 Y:1998 04 1998 ADJUST BURNERS FOR EFFICIENT OPERATION $341 $600 Implemented
BD0107 # 04 Y:1998 04 1998 INSTALL AUTOMATIC STACK DAMPER $1,388 $2,500 Not Implemented
BD0101 # 03 Y:1998 03 1998 INSTALL AUTOMATIC STACK DAMPER $6,809 $2,100 Not Implemented