IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,540

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0235 # 08 Y:1999 08 1999 DIRECT WARMEST AIR TO COMBUSTION INTAKE $431 $650 Not Implemented
BD0138 # 01 Y:1999 01 1999 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $32,466 $119,000 Not Implemented
IA0233 # 05 Y:1999 05 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,757 $2,000 Implemented
ORS005 # 05 Y:1999 05 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,920 $700 Implemented
SF0172 # 01 Y:1999 01 1999 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $7,540 $0 Implemented
NC0172 # 02 Y:1999 02 1999 OPERATE BOILERS ON HIGH FIRE SETTING $4,485 $0 Not Implemented
ORS003 # 05 Y:1999 05 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,140 $700 Implemented
ORS002 # 04 Y:1999 04 1999 REPLACE BOILER $12,100 $0 Implemented
ORS001 # 06 Y:1999 06 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,829 $700 Implemented
GT0671 # 03 Y:1999 03 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $20,745 $900 Not Implemented
IA0231 # 08 Y:1999 08 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,439 $2,000 Not Implemented
IA0231 # 09 Y:1999 09 1999 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,231 $800 Not Implemented
MA0445 # 03 Y:1999 03 1999 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,546 $472 Implemented
WI0353 # 02 Y:1999 02 1999 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $21,494 $72,000 Not Implemented
WI0357 # 04 Y:1999 04 1999 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $24,655 $10,800 Implemented
BD0141 # 04 Y:1999 04 1999 INSTALL TURBULATORS $466 $840 Not Implemented
KU0524 # 01 Y:1999 01 1999 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,520 $18,350 Implemented
KU0524 # 02 Y:1999 02 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,110 $2,500 Implemented
OR0354 # 03 Y:1999 03 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $750 $500 Implemented
UF0231 # 05 Y:1999 05 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,198 $1,000 Implemented
WV0178 # 08 Y:1999 08 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,578 $1,000 Not Implemented
NV0133 # 01 Y:1999 01 1999 REPLACE BOILER $20,745 $14,694 Implemented
MO0259 # 01 Y:1999 01 1999 REPLACE BOILER $16,318 $2,000 Implemented
WV0174 # 08 Y:1999 08 1999 REPLACE BOILER $1,371 $9,000 Not Implemented
IA0224 # 06 Y:1999 06 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $240 $600 n/a