Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsARC | 2.26 | COOLING |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0754 # 09 Y:2007 | 09 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $8,086 | $0 | Implemented |
OK0753 # 07 Y:2007 | 07 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $3,437 | $13,500 | Not Implemented |
WV0366 # 15 Y:2007 | 15 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $751 | $1,641 | Not Implemented |
WV0366 # 12 Y:2007 | 12 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,770 | $5,600 | Not Implemented |
MA0624 # 04 Y:2007 | 04 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $14,298 | $11,500 | Implemented |
UA0011 # 07 Y:2007 | 07 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,174 | $0 | Not Implemented |
UD0767 # 06 Y:2007 | 06 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,922 | $5,000 | Not Implemented |
BD0332 # 07 Y:2007 | 07 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,182 | $2 | Not Implemented |
OK0752 # 09 Y:2007 | 09 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $20,273 | $2,500 | Not Implemented |
WV0364 # 13 Y:2007 | 13 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,174 | $2,445 | Not Implemented |
LE0262 # 03 Y:2007 | 03 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $173,079 | $300,000 | Not Implemented |
OK0750 # 04 Y:2007 | 04 | 2007 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $8,272 | $16,000 | Not Implemented |
MI0155 # 07 Y:2007 | 07 | 2007 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $7,524 | $7,800 | Not Implemented |
MI0155 # 01 Y:2007 | 01 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $66,401 | $120,000 | Not Implemented |
LE0259 # 05 Y:2007 | 05 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,811 | $200 | Implemented |
UA0007 # 14 Y:2007 | 14 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $768 | $0 | Not Implemented |
UA0007 # 11 Y:2007 | 11 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,335 | $7,017 | Not Implemented |
MI0154 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $99,787 | $131,000 | Not Implemented |
MI0153 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $342,569 | $290,000 | Not Implemented |
UA0005 # 12 Y:2007 | 12 | 2007 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $34,728 | $1,615 | Not Implemented |
DL0002 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $19,418 | $73,950 | Not Implemented |
WV0360 # 08 Y:2007 | 08 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,676 | $3,700 | Implemented |
MA0619 # 05 Y:2007 | 05 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $14,883 | $5,300 | Not Implemented |
UD0763 # 05 Y:2007 | 05 | 2007 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $2,275 | $0 | Not Implemented |
LE0254 # 02 Y:2007 | 02 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $67,570 | $67,000 | Not Implemented |