Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

405

matching recommendations
Reset
ARC 2.262 Chillers and Refrigeration
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ORS004 # 01 Y:1999 01 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $24,048 $0 Implemented
ORS003 # 03 Y:1999 03 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $39,677 $20,000 Implemented
ORS001 # 05 Y:1999 05 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $6,070 $0 Implemented
OR0351 # 03 Y:1999 03 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,590 $0 Implemented
GT0669 # 07 Y:1999 07 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $8,844 $32,000 Implemented
ND0324 # 03 Y:1999 03 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,258 $30,000 Implemented
CO0439 # 01 Y:1999 01 1999 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $187,200 $13,080 Implemented
ME0266 # 01 Y:1999 01 1999 UTILIZE A LESS EXPENSIVE COOLING METHOD $26,281 $10,500 Implemented
UM0137 # 01 Y:1999 01 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $420 $0 Implemented
NC0142 # 07 Y:1998 07 1998 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $2,435 $10 Implemented
NV0105 # 03 Y:1998 03 1998 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $2,061 $0 Implemented
BD0118 # 01 Y:1998 01 1998 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $32,188 $123,000 Implemented
OD0107 # 02 Y:1998 02 1998 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $3,580 $100 Implemented
OR0304 # 06 Y:1997 06 1997 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,300 $0 Implemented
OD0092 # 01 Y:1997 01 1997 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $32,105 $53,256 Implemented
UF0185 # 04 Y:1997 04 1997 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $11,382 $32,000 Implemented
DS0094 # 01 Y:1997 01 1997 UTILIZE A LESS EXPENSIVE COOLING METHOD $57,050 $532,891 Implemented
DS0090 # 04 Y:1997 04 1997 UTILIZE A LESS EXPENSIVE COOLING METHOD $16,937 $20,000 Implemented
IA0164 # 06 Y:1997 06 1997 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,860 $1,788 Implemented
OR0288 # 03 Y:1997 03 1997 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $5,140 $0 Implemented
OR0281 # 07 Y:1996 07 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $10,430 $50,000 Implemented
AS0193 # 01 Y:1996 01 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $34,527 $45,000 Implemented
OR0279 # 01 Y:1996 01 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,604 $0 Implemented
AS0190 # 06 Y:1996 06 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $190,648 $100,000 Implemented
GT0594 # 05 Y:1996 05 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $112,836 $405,000 Implemented