Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,225

matching recommendations
Reset
ARC 2.262 Chillers and Refrigeration
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0278 # 02 Y:1996 02 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $6,050 $29,160 Implemented
WV0095 # 02 Y:1996 02 1996 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,565 $550 Implemented
WI0269 # 09 Y:1996 09 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,973 $6,000 Not Implemented
KG0062 # 03 Y:1996 03 1996 AVOID FROST FORMATION ON EVAPORATORS $12,480 $4,500 Not Implemented
KG0062 # 05 Y:1996 05 1996 AVOID FROST FORMATION ON EVAPORATORS $1,596 $3,000 Implemented
WI0268 # 02 Y:1996 02 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $5,104 $0 Not Implemented
AS0175 # 04 Y:1996 04 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $27,635 $25,000 Not Implemented
WI0267 # 04 Y:1996 04 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $13,635 $39,000 n/a
NC0085 # 01 Y:1996 01 1996 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $144 $0 Not Implemented
WI0265 # 08 Y:1996 08 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $954 $4,000 Not Implemented
KG0055 # 02 Y:1996 02 1996 AVOID FROST FORMATION ON EVAPORATORS $6,153 $0 Implemented
MA0358 # 05 Y:1996 05 1996 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $377 $0 Not Implemented
AS0168 # 06 Y:1996 06 1996 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $11,824 $0 Implemented
OR0258 # 01 Y:1996 01 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,070 $0 Not Implemented
OR0258 # 02 Y:1996 02 1996 UTILIZE A LESS EXPENSIVE COOLING METHOD $24,560 $120,600 Not Implemented
WI0256 # 06 Y:1996 06 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,370 $5,000 Not Implemented
NC0078 # 04 Y:1996 04 1996 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,344 $0 Implemented
UF0139 # 06 Y:1996 06 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $16,271 $35,000 Not Implemented
WV0079 # 03 Y:1996 03 1996 UTILIZE A LESS EXPENSIVE COOLING METHOD $19,407 $65,000 Not Implemented
KG0058 # 04 Y:1996 04 1996 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $5,489 $60 Not Implemented
KG0059 # 01 Y:1996 01 1996 AVOID FROST FORMATION ON EVAPORATORS $65,997 $15,000 Not Implemented
SD0131 # 02 Y:1996 02 1996 AVOID FROST FORMATION ON EVAPORATORS $18,229 $1,000 Implemented
AR0075 # 08 Y:1995 08 1995 UTILIZE A LESS EXPENSIVE COOLING METHOD $2,520 $2,092 Implemented
WI0253 # 04 Y:1995 04 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,365 $7,000 n/a
AS0164 # 01 Y:1995 01 1995 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,560 $4,976 Not Implemented