Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

227

matching recommendations
Reset
ARC 2.3 Electrical Power
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0224 # 02 Y:2001 02 2001 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $16,136 $45,000 Not Implemented
LE0121 # 01 Y:2001 01 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $13,570 $2,500 Implemented
SF0224 # 12 Y:2001 12 2001 OPTIMIZE PLANT POWER FACTOR $120,158 $160,000 n/a
NC0223 # 06 Y:2001 06 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,524 $40,000 Not Implemented
LL0119 # 04 Y:2001 04 2001 OPTIMIZE PLANT POWER FACTOR $45,054 $173,974 Implemented
WI0406 # 02 Y:2001 02 2001 OPTIMIZE PLANT POWER FACTOR $7,981 $14,550 Not Implemented
OR0397 # 05 Y:2001 05 2001 OPTIMIZE PLANT POWER FACTOR $2,426 $4,000 Not Implemented
UM0196 # 02 Y:2001 02 2001 OPTIMIZE PLANT POWER FACTOR $8,645 $19,064 Implemented
CO0488 # 02 Y:2001 02 2001 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,300 $6,000 Not Implemented
MA0495 # 02 Y:2001 02 2001 OPTIMIZE PLANT POWER FACTOR $1,530 $2,100 Not Implemented
LL0121 # 02 Y:2001 02 2001 OPTIMIZE PLANT POWER FACTOR $4,301 $15,406 Not Implemented
OR0395 # 02 Y:2001 02 2001 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $367,000 $2,750,000 Not Implemented
LL0120 # 03 Y:2001 03 2001 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $205,089 $425,809 n/a
UD0632 # 01 Y:2001 01 2001 OPTIMIZE PLANT POWER FACTOR $94,812 $8,000 Implemented
WI0404 # 07 Y:2001 07 2001 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $135 $400 Implemented
UU0012 # 04 Y:2001 04 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,600 $5,000 Implemented
IC0015 # 10 Y:2001 10 2001 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $162 $0 Implemented
CO0487 # 02 Y:2001 02 2001 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,240 $18,000 Not Implemented
CO0487 # 01 Y:2001 01 2001 OPTIMIZE PLANT POWER FACTOR $11,370 $13,000 Not Implemented
TA0012 # 01 Y:2001 01 2001 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $14,730 $0 Implemented
MS0190 # 03 Y:2001 03 2001 OPTIMIZE PLANT POWER FACTOR $9,338 $9,000 n/a
UD0631 # 10 Y:2001 10 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $904 $0 Not Implemented
UD0631 # 05 Y:2001 05 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,067 $7,000 Not Implemented
SF0223 # 13 Y:2001 13 2001 OPTIMIZE PLANT POWER FACTOR $13,899 $20,315 Not Implemented
LE0122 # 02 Y:2001 02 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,672 $2,500 Not Implemented