Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,575
matching recommendationsARC | 3 | WASTE MINIMIZATION / POLLUTION PREVENTION |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0503 # 06 Y:2006 | 06 | 2006 | REUSE RAGS UNTIL COMPLETELY SOILED | $880 | $0 | Not Implemented |
IA0380 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $298 | $650 | Not Implemented |
IA0380 # 06 Y:2006 | 06 | 2006 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $11,632 | $4,000 | Not Implemented |
OK0720 # 03 Y:2006 | 03 | 2006 | INCREASE USE OF AUTOMATION | $10,975 | $6,000 | Not Implemented |
AM0502 # 02 Y:2006 | 02 | 2006 | REUSE RAGS UNTIL COMPLETELY SOILED | $82,500 | $0 | Implemented |
UF0373 # 07 Y:2006 | 07 | 2006 | RECYCLE FLUORESCENT LAMPS | $312 | $3,496 | Not Implemented |
BD0297 # 12 Y:2006 | 12 | 2006 | RECOVER AND REUSE COOLING WATER | $42,543 | $36,180 | Implemented |
SD0375 # 07 Y:2006 | 07 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,700 | $18,500 | Not Implemented |
AM0500 # 08 Y:2006 | 08 | 2006 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $430 | $0 | Implemented |
CO0580 # 06 Y:2006 | 06 | 2006 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,460 | $9,360 | Not Implemented |
SU0228 # 04 Y:2006 | 04 | 2006 | INCREASE USE OF AUTOMATION | $1,765,875 | $3,500,000 | Implemented |
SU0226 # 08 Y:2006 | 08 | 2006 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $53,622 | $114,259 | n/a |
SU0228 # 03 Y:2006 | 03 | 2006 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $39,585 | $111,774 | Implemented |
UU0092 # 01 Y:2005 | 01 | 2005 | USE SOY OR WATER-BASED INKS | $28,070 | $20,000 | Not Implemented |
AM0499 # 02 Y:2005 | 02 | 2005 | REUSE RAGS UNTIL COMPLETELY SOILED | $12,000 | $0 | Implemented |
TA0110 # 05 Y:2005 | 05 | 2005 | USE EVAPORATION TO CONCENTRATE MATERIAL | $4,083 | $5,319 | Not Implemented |
CO0579 # 01 Y:2005 | 01 | 2005 | TREAT AND REUSE RINSE WATERS | $5,020 | $8,800 | Not Implemented |
UF0370 # 11 Y:2005 | 11 | 2005 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,313 | $0 | Implemented |
UU0096 # 05 Y:2005 | 05 | 2005 | RECOVER AND REUSE WASTE MATERIAL | $9,000 | $0 | Not Implemented |
WI0502 # 03 Y:2005 | 03 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,880 | $0 | Not Implemented |
WI0502 # 04 Y:2005 | 04 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,880 | $0 | Not Implemented |
BD0296 # 10 Y:2005 | 10 | 2005 | USE AN ALTERNATIVE DESULFURIZING AGENT TO ELIMINATE HAZARDOUS SLAG FORMATION | $192,926 | $3,000 | Implemented |
SF0318 # 08 Y:2005 | 08 | 2005 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $13 | $10,000 | Implemented |
AM0498 # 04 Y:2005 | 04 | 2005 | REUSE RAGS UNTIL COMPLETELY SOILED | $1,580 | $0 | Implemented |
SF0318 # 09 Y:2005 | 09 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4 | $16,945 | Not Implemented |