Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
119
matching recommendationsARC | 3. | WASTE MINIMIZATION / POLLUTION PREVENTION |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0831 # 04 Y:2006 | 04 | 2006 | MINIMIZE WATER USAGE | $17,245 | $1,500 | Not Implemented |
GT0833 # 02 Y:2006 | 02 | 2006 | ELIMINATE/REDUCE AN OPERATION | $137,445 | $0 | Not Implemented |
GT0833 # 05 Y:2006 | 05 | 2006 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $29,400 | $0 | Implemented |
IC0123 # 05 Y:2006 | 05 | 2006 | TREAT AND REUSE RINSE WATERS | $92,357 | $31,583 | Not Implemented |
OR0510 # 01 Y:2006 | 01 | 2006 | CAREFULLY CONTROL WATER LEVEL IN MASS FINISHING EQUIPMENT | $61,000 | $40,000 | Implemented |
TA0132 # 03 Y:2006 | 03 | 2006 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,293 | $35 | Not Implemented |
NC0349 # 08 Y:2006 | 08 | 2006 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $5,891 | $4,000 | Not Implemented |
GT0827 # 08 Y:2006 | 08 | 2006 | METER WASTE WATER | $81,583 | $5,250 | Implemented |
UU0106 # 05 Y:2006 | 05 | 2006 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $23,010 | $7,390 | Not Implemented |
AM0518 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,000 | $415 | Implemented |
AM0518 # 04 Y:2006 | 04 | 2006 | REUSE RAGS UNTIL COMPLETELY SOILED | $3,850 | $0 | Implemented |
LE0246 # 02 Y:2006 | 02 | 2006 | REUSE RICH WHITE WATER IN OTHER APPLICATIONS | $14,590 | $20,000 | Not Implemented |
LE0246 # 04 Y:2006 | 04 | 2006 | MINIMIZE WATER USAGE | $6,264 | $1,800 | Not Implemented |
OR0507 # 08 Y:2006 | 08 | 2006 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $32,400 | $23,200 | Not Implemented |
OR0504 # 04 Y:2006 | 04 | 2006 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $28,000 | $0 | Not Implemented |
LE0247 # 02 Y:2006 | 02 | 2006 | REVISE RAW MATERIAL SPECS | $106,250 | $60,000 | Not Implemented |
OR0504 # 03 Y:2006 | 03 | 2006 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $84,100 | $0 | Not Implemented |
OR0503 # 05 Y:2006 | 05 | 2006 | MAXIMIZE PRODUCTION RUNS TO REDUCE CLEANING | $46,500 | $0 | Implemented |
WV0350 # 12 Y:2006 | 12 | 2006 | BURN WASTE OIL FOR HEAT | $2,316 | $1,180 | Not Implemented |
WI0525 # 03 Y:2006 | 03 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,600 | $0 | Not Implemented |
UM0311 # 01 Y:2006 | 01 | 2006 | BURN WASTE PAPER FOR HEAT | $109,604 | $27,325 | Not Implemented |
SF0335 # 14 Y:2006 | 14 | 2006 | ELIMINATE/REDUCE AN OPERATION | $34,191 | $22,085 | Not Implemented |
MS0303 # 03 Y:2006 | 03 | 2006 | BURN WASTE OIL FOR HEAT | $3,804 | $2,186 | Implemented |
UU0105 # 08 Y:2006 | 08 | 2006 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $15,140 | $40,000 | Not Implemented |
IC0119 # 01 Y:2006 | 01 | 2006 | RECOVER AND REUSE SPENT ACID BATHS | $32,160 | $82,800 | Not Implemented |