Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,476

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0112 # 03 Y:1997 03 1997 DIRECT WARMEST AIR TO COMBUSTION INTAKE $223 $88 n/a
TN0605 # 03 Y:1997 03 1997 KEEP BOILER TUBES CLEAN $39,970 $70,960 Implemented
DS0086 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $960 $0 Implemented
OR0292 # 05 Y:1997 05 1997 KEEP BOILER TUBES CLEAN $7,179 $500 Implemented
NC0109 # 05 Y:1997 05 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,281 $1,200 Implemented
OK0519 # 01 Y:1997 01 1997 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $178,301 $18,000 Implemented
OK0518 # 02 Y:1997 02 1997 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $7,965 $5,000 Implemented
WV0113 # 07 Y:1997 07 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,000 $500 Implemented
GT0609 # 03 Y:1997 03 1997 REDUCE EXCESSIVE BOILER BLOWDOWN $3,060 $0 Not Implemented
OD0079 # 07 Y:1997 07 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $676 $1,495 Not Implemented
DS0083 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,832 $1,000 Not Implemented
OD0078 # 05 Y:1997 05 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,337 $1,495 Implemented
WI0290 # 08 Y:1997 08 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,333 $500 Implemented
SD0164 # 03 Y:1997 03 1997 REPLACE BOILER $204,328 $78,000 Not Implemented
WV0109 # 05 Y:1997 05 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $26,265 $3,000 Implemented
WV0109 # 06 Y:1997 06 1997 DIRECT WARMEST AIR TO COMBUSTION INTAKE $7,904 $6,300 Implemented
ND0268 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,416 $3,000 n/a
AM0291 # 07 Y:1997 07 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,060 $500 Implemented
AM0290 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,310 $500 Implemented
SF0106 # 05 Y:1997 05 1997 DIRECT WARMEST AIR TO COMBUSTION INTAKE $912 $2,750 Not Implemented
OR0291 # 09 Y:1997 09 1997 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $2,590 $11,350 Not Implemented
SD0161 # 02 Y:1997 02 1997 REPLACE BOILER $38,307 $8,000 Not Implemented
AM0288 # 07 Y:1997 07 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $430 $420 Implemented
NC0106 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,634 $1,200 Implemented
OD0076 # 01 Y:1997 01 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,337 $1,495 Not Implemented