Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0327 # 01 Y:1999 01 1999 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $17,546 $25,000 Implemented
MS0140 # 04 Y:1999 04 1999 RECOVER WASTE HEAT FROM EQUIPMENT $2,213 $2,922 Implemented
MS0140 # 03 Y:1999 03 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $4,814 $1,440 Not Implemented
AM0353 # 09 Y:1999 09 1999 INSULATE BARE EQUIPMENT $1,030 $81 Implemented
WV0175 # 03 Y:1999 03 1999 REPAIR OR REPLACE STEAM TRAPS $426,829 $88,360 Implemented
WV0174 # 06 Y:1999 06 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $69,389 $17,840 Not Implemented
ND0324 # 03 Y:1999 03 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,258 $30,000 Implemented
SD0234 # 03 Y:1999 03 1999 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,768 $13,000 Not Implemented
SD0233 # 04 Y:1999 04 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,392 $1,394 Implemented
GT0667 # 04 Y:1999 04 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $62 $200 Not Implemented
GT0667 # 03 Y:1999 03 1999 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $182 $0 Not Implemented
HO0209 # 04 Y:1999 04 1999 USE OPTIMUM THICKNESS INSULATION $24,609 $13,620 Not Implemented
UM0144 # 05 Y:1999 05 1999 USE OPTIMUM THICKNESS INSULATION $1,848 $2,100 Not Implemented
MS0139 # 03 Y:1999 03 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $61,739 $26,241 Implemented
HO0209 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $3,541 $1,468 Not Implemented
SD0232 # 04 Y:1999 04 1999 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $6,905 $7,400 Not Implemented
KU0520 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $410 $670 Not Implemented
KU0519 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $1,140 $680 Not Implemented
SD0231 # 02 Y:1999 02 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,622 $3,600 Not Implemented
MS0138 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,777 $1,994 Implemented
TN0664 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $473 $825 Not Implemented
KU0519 # 01 Y:1999 01 1999 USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC $8,170 $11,490 Not Implemented
HO0208 # 07 Y:1999 07 1999 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $4,536 $700 n/a
ME0270 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $316 $804 Not Implemented
KU0518 # 01 Y:1999 01 1999 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $15,510 $29,690 Not Implemented