Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,679
matching recommendationsARC | 3.4 | Water Use |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0358 # 01 Y:1999 | 01 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $97,790 | $44,000 | Implemented |
NC0170 # 04 Y:1999 | 04 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,763 | $200 | Not Implemented |
AR0168 # 03 Y:1999 | 03 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $11,649 | $7,750 | Not Implemented |
NC0170 # 06 Y:1999 | 06 | 1999 | MINIMIZE WATER USAGE | $3,900 | $50 | Not Implemented |
WI0353 # 04 Y:1999 | 04 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,159 | $22,000 | Implemented |
TP0005 # 04 Y:1999 | 04 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,671 | $7,300 | Implemented |
ND0330 # 09 Y:1999 | 09 | 1999 | MINIMIZE WATER USAGE | $821 | $960 | Not Implemented |
DS0147 # 06 Y:1999 | 06 | 1999 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,498 | $2,832 | Not Implemented |
ND0326 # 08 Y:1999 | 08 | 1999 | MINIMIZE WATER USAGE | $912 | $1,760 | Not Implemented |
UM0148 # 04 Y:1999 | 04 | 1999 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $12,311 | $40,000 | Implemented |
TP0004 # 07 Y:1999 | 07 | 1999 | RECOVER AND REUSE COOLING WATER | $1,313 | $1,224 | n/a |
TP0004 # 01 Y:1999 | 01 | 1999 | METER WASTE WATER | $87,413 | $6,200 | n/a |
TP0004 # 02 Y:1999 | 02 | 1999 | MINIMIZE WATER USAGE | $9,617 | $655 | n/a |
TP0004 # 06 Y:1999 | 06 | 1999 | MINIMIZE WATER USAGE | $1,664 | $388 | n/a |
UD0578 # 06 Y:1999 | 06 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,242 | $0 | Implemented |
SD0230 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $83,680 | $0 | Implemented |
ND0329 # 06 Y:1999 | 06 | 1999 | MINIMIZE WATER USAGE | $870 | $1,400 | Not Implemented |
ND0329 # 07 Y:1999 | 07 | 1999 | MINIMIZE WATER USAGE | $878 | $2,300 | Not Implemented |
BD0140 # 10 Y:1999 | 10 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,427 | $3,000 | Not Implemented |
BD0140 # 09 Y:1999 | 09 | 1999 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $30,353 | $10,000 | Implemented |
BD0140 # 11 Y:1999 | 11 | 1999 | MINIMIZE WATER USAGE | $1,471 | $2,590 | Implemented |
CO0444 # 04 Y:1999 | 04 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $19,000 | $21,600 | Not Implemented |
NC0168 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $34,792 | $5,000 | Not Implemented |
NC0168 # 05 Y:1999 | 05 | 1999 | METER WASTE WATER | $16,740 | $3,500 | Not Implemented |
ME0271 # 09 Y:1999 | 09 | 1999 | METER WASTE WATER | $1,684 | $200 | Implemented |