Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,506
matching recommendationsARC | 2.12 | BOILERS |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0374 # 08 Y:2000 | 08 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,394 | $500 | Implemented |
OD0159 # 05 Y:2000 | 05 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,786 | $1,500 | n/a |
IA0241 # 03 Y:2000 | 03 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,987 | $2,000 | Not Implemented |
IA0241 # 04 Y:2000 | 04 | 2000 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,474 | $1,474 | Not Implemented |
DS0162 # 02 Y:2000 | 02 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $762 | $0 | n/a |
TP0015 # 01 Y:2000 | 01 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,906 | $600 | Implemented |
WI0371 # 11 Y:2000 | 11 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $282 | $500 | Implemented |
WI0370 # 09 Y:2000 | 09 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $627 | $500 | Not Implemented |
SD0241 # 03 Y:2000 | 03 | 2000 | REDUCE EXCESSIVE BOILER BLOWDOWN | $2,831 | $6,150 | Implemented |
SD0241 # 01 Y:2000 | 01 | 2000 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $9,946 | $24,320 | Implemented |
BD0157 # 02 Y:2000 | 02 | 2000 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $2,952 | $4,600 | Not Implemented |
NV0148 # 01 Y:2000 | 01 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $768 | $1,500 | Implemented |
WV0183 # 06 Y:2000 | 06 | 2000 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $14,087 | $10,840 | Not Implemented |
WV0183 # 07 Y:2000 | 07 | 2000 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $34,536 | $10,840 | Not Implemented |
WV0183 # 10 Y:2000 | 10 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $18,683 | $1,000 | Implemented |
TN0652 # 10 Y:1999 | 10 | 1999 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $16,210 | $10,000 | Not Implemented |
SD0237 # 03 Y:2000 | 03 | 2000 | REDUCE EXCESSIVE BOILER BLOWDOWN | $688 | $100 | Implemented |
UM0158 # 04 Y:2000 | 04 | 2000 | REDUCE EXCESSIVE BOILER BLOWDOWN | $11,891 | $9,860 | Not Implemented |
UM0157 # 03 Y:2000 | 03 | 2000 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,224 | $4,430 | Implemented |
GT0678 # 02 Y:1999 | 02 | 1999 | REDUCE EXCESSIVE BOILER BLOWDOWN | $920 | $900 | Not Implemented |
CO0456 # 04 Y:2000 | 04 | 2000 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $930 | $1,400 | n/a |
UM0156 # 04 Y:2000 | 04 | 2000 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,813 | $4,430 | Not Implemented |
UM0156 # 06 Y:2000 | 06 | 2000 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $7,640 | $6,500 | Implemented |
MO0273 # 02 Y:2000 | 02 | 2000 | REPLACE BOILER | $35,241 | $30,000 | Implemented |
OD0152 # 08 Y:2000 | 08 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $452 | $1,000 | Not Implemented |