Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

69

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KS2438 # 07 Y:2024 07 2024 REPLACE BOILER $50,929 $423,280 n/a
CI0042 # 02 Y:2024 02 2024 REPLACE BOILER $66,255 $50,000 n/a
AS0596 # 06 Y:2024 06 2024 KEEP BOILER TUBES CLEAN $47 $83 n/a
AS0592 # 02 Y:2024 02 2024 REPLACE BOILER $56,229 $300,000 n/a
OR0804 # 03 Y:2024 03 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,548 $0 n/a
UF0623 # 06 Y:2024 06 2024 INSTALL TURBULATORS $979 $3,750 n/a
WV0674 # 04 Y:2024 04 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $696 $1,133 Implemented
OR0802 # 04 Y:2024 04 2024 REPLACE BOILER $37,073 $222,038 n/a
NT0034 # 05 Y:2024 05 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,461 $1,258 Implemented
WV0670 # 11 Y:2024 11 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $237 $1,029 Implemented
UU0258 # 01 Y:2024 01 2024 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $158,000 $725,000 n/a
SF0627 # 11 Y:2024 11 2024 REDUCE EXCESSIVE BOILER BLOWDOWN $758 $3,995 n/a
SJ0026 # 09 Y:2024 09 2024 REDUCE EXCESSIVE BOILER BLOWDOWN $2,261 $1,017 n/a
WV0671 # 14 Y:2024 14 2024 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $314 $1,322 Not Implemented
TT0317 # 10 Y:2024 10 2024 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $56,902 $80,000 n/a
SD0661 # 12 Y:2024 12 2024 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $12,725 $11,775 Not Implemented
MU0058 # 01 Y:2024 01 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $135 $370 Not Implemented
UC2413 # 06 Y:2024 06 2024 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $4,482 $16,784 n/a
WV0669 # 11 Y:2024 11 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,467 $940 Implemented
SD0660 # 07 Y:2024 07 2024 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $2,963 $0 Not Implemented
WV0668 # 04 Y:2024 04 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,250 $773 Implemented
WV0667 # 01 Y:2024 01 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,417 $2,917 Implemented
WV0667 # 02 Y:2024 02 2024 INSTALL TURBULATORS $6,784 $4,404 Not Implemented
NL0098 # 01 Y:2024 01 2024 REPLACE BOILER $6,690 $32,200 n/a
NT0030 # 07 Y:2024 07 2024 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,747 $1,279 Implemented