Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

142

matching recommendations
Reset
ARC 2.725 Evaporation
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0500 # 03 Y:2002 03 2002 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $2,640 $5,750 Not Implemented
NC0226 # 08 Y:2001 08 2001 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $93,403 $-312,000 Not Implemented
NC0211 # 01 Y:2001 01 2001 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $23,426 $20,000 Implemented
WI0394 # 04 Y:2001 04 2001 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $4,549 $9,975 n/a
TN0696 # 02 Y:2000 02 2000 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $182,800 $173,400 Not Implemented
WI0382 # 01 Y:2000 01 2000 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $11,648 $23,400 Not Implemented
TN0694 # 04 Y:2000 04 2000 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $10,130 $181,580 Not Implemented
WI0381 # 01 Y:2000 01 2000 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $10,973 $29,550 Not Implemented
NC0194 # 03 Y:2000 03 2000 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $13,561 $29,000 Implemented
GT0694 # 09 Y:2000 09 2000 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $2,967 $9,200 Not Implemented
WI0371 # 01 Y:2000 01 2000 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $24,407 $25,200 Not Implemented
WI0360 # 04 Y:1999 04 1999 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $7,161 $40,800 Not Implemented
WI0336 # 08 Y:1999 08 1999 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $2,805 $8,400 Not Implemented
WI0338 # 03 Y:1999 03 1999 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $4,369 $7,590 n/a
OK0555 # 08 Y:1998 08 1998 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $5,557 $25,000 Not Implemented
WI0326 # 04 Y:1998 04 1998 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $7,874 $12,186 Not Implemented
WI0313 # 01 Y:1998 01 1998 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $4,445 $7,155 Implemented
KU0481 # 01 Y:1997 01 1997 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $30,340 $21,800 Not Implemented
WI0289 # 05 Y:1997 05 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $6,780 $34,425 Not Implemented
KG0082 # 01 Y:1997 01 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $9,336 $250 n/a
KG0080 # 02 Y:1997 02 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $5,869 $500 n/a
KG0079 # 02 Y:1997 02 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $4,649 $500 n/a
WI0286 # 08 Y:1997 08 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $2,230 $10,230 Not Implemented
WI0285 # 06 Y:1996 06 1996 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $2,549 $10,500 Not Implemented
WI0274 # 03 Y:1996 03 1996 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $3,082 $10,500 Implemented