Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,630

matching recommendations
Reset
ARC 2.11 FURNACES, OVENS AND DIRECTLY FIRED OPERATIONS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0235 # 11 Y:2006 11 2006 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $9,908 $7,500 Implemented
LL0251 # 01 Y:2006 01 2006 CONVERT TO OXYFUEL BURNERS $457,261 $150,000 Not Implemented
UD0741 # 01 Y:2006 01 2006 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $65,250 $10,000 Not Implemented
UD0741 # 05 Y:2006 05 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $9,135 $2,800 Implemented
OR0499 # 01 Y:2006 01 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $77,273 $12,000 Implemented
NC0336 # 03 Y:2006 03 2006 ADJUST BURNERS FOR EFFICIENT OPERATION $2,620 $1,500 Not Implemented
OK0726 # 09 Y:2006 09 2006 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $579 $2,006 Not Implemented
NC0334 # 02 Y:2006 02 2006 ADJUST BURNERS FOR EFFICIENT OPERATION $2,870 $1,000 Implemented
LE0231 # 09 Y:2006 09 2006 IMPROVE COMBUSTION CONTROL CAPABILITY $7,881 $2,500 Implemented
OK0723 # 03 Y:2006 03 2006 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,135 $587 Implemented
GT0818 # 05 Y:2006 05 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $37,004 $3,300 Not Implemented
LE0226 # 04 Y:2006 04 2006 IMPROVE COMBUSTION CONTROL CAPABILITY $64,647 $2,500 Not Implemented
IA0381 # 16 Y:2006 16 2006 ADJUST BURNERS FOR EFFICIENT OPERATION $6,473 $1,000 Implemented
UD0732 # 08 Y:2006 08 2006 IMPROVE COMBUSTION CONTROL CAPABILITY $9,263 $0 Implemented
OK0720 # 02 Y:2006 02 2006 ADJUST BURNERS FOR EFFICIENT OPERATION $10,780 $4,636 Implemented
LM0110 # 04 Y:2006 04 2006 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $85,569 $90,000 Not Implemented
MI0120 # 01 Y:2006 01 2006 IMPROVE COMBUSTION CONTROL CAPABILITY $178,061 $75,000 Not Implemented
OR0498 # 02 Y:2006 02 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,300 $0 Not Implemented
GT0815 # 03 Y:2005 03 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $62,800 $36,000 Not Implemented
IC0110 # 05 Y:2005 05 2005 IMPROVE COMBUSTION CONTROL CAPABILITY $13,789 $3,500 Implemented
GT0814 # 02 Y:2005 02 2005 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $235,000 $20,000 Not Implemented
NC0328 # 01 Y:2005 01 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $8,068 $6,225 Not Implemented
CO0577 # 03 Y:2005 03 2005 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $89,400 $41,000 Implemented
LE0225 # 02 Y:2005 02 2005 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $17,500 $50,000 Implemented
LE0225 # 07 Y:2005 07 2005 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,914 $2,500 Implemented