Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

40

matching recommendations
Reset
ARC 2.11 FURNACES, OVENS AND DIRECTLY FIRED OPERATIONS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0605 # 02 Y:2000 02 2000 IMPROVE COMBUSTION CONTROL CAPABILITY $606,630 $500,000 Not Implemented
OK0605 # 01 Y:2000 01 2000 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $6,168,500 $723,000 Not Implemented
GT0705 # 01 Y:2000 01 2000 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $37,979 $10,000 Not Implemented
CO0476 # 03 Y:2000 03 2000 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $2,310 $1,000 Implemented
OK0604 # 01 Y:2000 01 2000 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $7,686 $4,275 Implemented
GT0701 # 02 Y:2000 02 2000 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $23,600 $2,200 Not Implemented
NC0204 # 01 Y:2000 01 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $4,201 $2,350 Implemented
NC0205 # 05 Y:2000 05 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $10,548 $2,000 n/a
CO0473 # 01 Y:2000 01 2000 IMPROVE COMBUSTION CONTROL CAPABILITY $74,960 $1,050 Implemented
NV0164 # 02 Y:2000 02 2000 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $75,664 $100 n/a
WV0203 # 08 Y:2000 08 2000 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $337 $222 Implemented
NV0161 # 01 Y:2000 01 2000 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $12,740 $0 Not Implemented
AS0283 # 07 Y:2000 07 2000 INSTALL AUTOMATIC STACK DAMPER $766 $594 Not Implemented
NV0160 # 01 Y:2000 01 2000 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE $8,107 $370 n/a
WI0381 # 04 Y:2000 04 2000 INSTALL AUTOMATIC STACK DAMPER $1,157 $1,000 Implemented
KU0542 # 04 Y:2000 04 2000 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,730 $0 Implemented
NC0190 # 01 Y:2000 01 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $16,521 $3,000 n/a
BD0158 # 03 Y:2000 03 2000 INSTALL AUTOMATIC STACK DAMPER $1,929 $3,000 Implemented
NV0153 # 01 Y:2000 01 2000 IMPROVE COMBUSTION CONTROL CAPABILITY $3,058 $5,650 Not Implemented
WV0194 # 05 Y:2000 05 2000 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $2,224 $460 Implemented
WV0194 # 08 Y:2000 08 2000 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $4,605 $5,330 Implemented
SF0193 # 01 Y:2000 01 2000 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $11,245 $3,224 Not Implemented
WV0192 # 02 Y:2000 02 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $7,224 $1,645 Not Implemented
WV0192 # 04 Y:2000 04 2000 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $414 $65 Implemented
NC0189 # 01 Y:2000 01 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $1,081 $800 Implemented