IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

592

matching recommendations
Reset
ARC 2.242 Flue Gas - Other Uses
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0326 # 07 Y:2005 07 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $780 $1,076 Implemented
UD0726 # 08 Y:2005 08 2005 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $19,593 $40,000 Not Implemented
CO0570 # 06 Y:2005 06 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $7,880 $8,110 Not Implemented
IC0107 # 01 Y:2005 01 2005 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $9,504 $19,598 Not Implemented
SD0370 # 01 Y:2005 01 2005 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $19,420 $28,950 Not Implemented
WI0495 # 07 Y:2005 07 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,135 $1,500 Implemented
WI0493 # 02 Y:2005 02 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $26,534 $11,200 Not Implemented
UM0280 # 04 Y:2005 04 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $2,274 $1,680 Not Implemented
SU0206 # 04 Y:2005 04 2005 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $255,262 $207,240 Implemented
IC0096 # 02 Y:2005 02 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $14,724 $46,000 Not Implemented
IC0095 # 04 Y:2005 04 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $16,405 $50,000 Not Implemented
UM0275 # 07 Y:2005 07 2005 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $4,883 $3,000 Implemented
UD0711 # 02 Y:2005 02 2005 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $143,601 $246,784 Not Implemented
GT0791 # 05 Y:2004 05 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $74,318 $31,600 n/a
GT0791 # 07 Y:2004 07 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $10,622 $17,600 n/a
AM0477 # 05 Y:2005 05 2005 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $5,200 $4,300 Not Implemented
UU0077 # 03 Y:2004 03 2004 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $14,890 $45,000 Implemented
IA0355 # 03 Y:2004 03 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $12,422 $17 Implemented
WI0480 # 07 Y:2004 07 2004 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $634 $1,500 Implemented
CO0554 # 04 Y:2004 04 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $3,550 $13,640 Not Implemented
IA0351 # 11 Y:2004 11 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $13,254 $18,000 Not Implemented
UM0268 # 02 Y:2004 02 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $3,888 $840 Implemented
UM0266 # 01 Y:2004 01 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $11,825 $4,500 Implemented
LE0197 # 05 Y:2004 05 2004 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $35,862 $150,000 Not Implemented
AM0471 # 02 Y:2004 02 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $6,640 $4,600 Implemented