IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

117

matching recommendations
Reset
ARC 2.3 Electrical Power
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0781 # 04 Y:2008 04 2008 OPTIMIZE PLANT POWER FACTOR $6,559 $9,000 Implemented
SF0356 # 02 Y:2008 02 2008 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $41,503 $0 Not Implemented
LE0269 # 07 Y:2008 07 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,734 $3,000 Not Implemented
GT0849 # 06 Y:2008 06 2008 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $228,740 $900,000 Not Implemented
CO0612 # 01 Y:2008 01 2008 USE DEMAND CONTROLLER OR LOAD SHEDDER $13,590 $59,400 Not Implemented
LE0270 # 08 Y:2008 08 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,349 $175,000 Implemented
WV0376 # 04 Y:2008 04 2008 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,524 $8,800 Implemented
UD0779 # 02 Y:2008 02 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $95,648 $1,000 Implemented
AM0548 # 02 Y:2008 02 2008 OPTIMIZE PLANT POWER FACTOR $12,300 $17,275 Not Implemented
UD0779 # 09 Y:2008 09 2008 OPTIMIZE PLANT POWER FACTOR $5,482 $3,000 Not Implemented
AM0547 # 02 Y:2008 02 2008 OPTIMIZE PLANT POWER FACTOR $27,000 $28,900 Not Implemented
AM0546 # 07 Y:2008 07 2008 OPTIMIZE PLANT POWER FACTOR $3,420 $7,755 Not Implemented
MA0637 # 06 Y:2008 06 2008 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $24,017 $14,000 Implemented
OR0528 # 07 Y:2008 07 2008 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $287,980 $314,400 Not Implemented
MA0636 # 05 Y:2008 05 2008 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $8,663 $5,000 Not Implemented
MA0636 # 03 Y:2008 03 2008 USE EXISTING DAM TO GENERATE ELECTRICITY $110,112 $939,500 Implemented
SD0405 # 01 Y:2008 01 2008 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $117,665 $1,117,600 Implemented
SD0404 # 09 Y:2008 09 2008 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $62,662 $213,472 Not Implemented
AM0542 # 03 Y:2008 03 2008 OPTIMIZE PLANT POWER FACTOR $12,000 $18,000 Not Implemented
SU0265 # 08 Y:2008 08 2008 OPTIMIZE PLANT POWER FACTOR $921 $4,079 Not Implemented
TT0021 # 01 Y:2008 01 2008 OPTIMIZE PLANT POWER FACTOR $3,500 $12,500 Implemented
WV0375 # 19 Y:2008 19 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,275 $0 Not Implemented
WV0375 # 09 Y:2008 09 2008 USE DEMAND CONTROLLER OR LOAD SHEDDER $57,494 $25,520 Not Implemented
NC0372 # 01 Y:2008 01 2008 OPTIMIZE PLANT POWER FACTOR $10,092 $8,000 Not Implemented
TT0016 # 01 Y:2008 01 2008 OPTIMIZE PLANT POWER FACTOR $17,400 $50,000 Implemented